Medium Voltase 150mm2 XLPE Kabel dengan Kawat Aluminium 33kV XLPE Insulated Udara Bundel Kabel
Pelabuhan: | Qingdao port for 33kv abc aerial bundle cable |
Ketentuan Pembayaran: | L/C,T/T,Western Union,MoneyGram |
Kemampuan Pasokan: | 2000 Kilometer/kilometer per Month 33kv ABC Aerial bundel kabel |
Tempat asal: | Henan Cina |
Nama merek: | Hongda Aluminum Wire |
Nomor model: | 33kv abc aerial bundle cable |
Bahan isolasi: | XLPE |
Jenis: | Tegangan menengah |
Aplikasi: | Overhead |
Bahan konduktor: | Aluminium |
Jaket: | no sheath |
Material: | alloy aluminum |
Mark: | CCC, IEC |
Standard: | AWG, IEC, BS, ASTM |
Using: | Overhead, power transmission lines |
Cable Type: | quadruplex service drop cable |
Conductor Type: | ACSR AAC AAAC ACAR |
Type: | 33kv abc aerial bundle cable |
Perincian Pengemasan: | Ekspor standar kayu drum setiap ujung kabel akan dengan kuat dan diamankan dengan benar ke drum untuk 33kv ABC udara bundel kabel |
MV Udara Dibundel Konduktor (ABC) Kabel
APLIKASI
Tegangan menengah Udara dibundel kabel terutama digunakan untuk sekunder garis overhead pada tiang atau pengumpan
Untuk tempat tinggal.
STANDAR
Desain dasar untuk IEC 60502/AS/NZS 3599-1 standar
KONSTRUKSI KABEL
Konduktor fase: Circular dipadatkan terdampar H68 aluminium untuk BS2627.
Konduktor Layar: Diekstrusi semi konduktif lapisan.
Isolasi: XLPE.
Isolasi Layar: Diekstrusi semi konduktif lapisan.
Logam Layar (opsional): kawat Tembaga layar atau pita tembaga.
Pemisah: Semi konduktif swellable tape.
Selubung luar: HDPE.
Dukungan Konduktor: Galvanis kawat baja.
Perakitan: Tiga XLPE insulated screened core yang dibundel di sekitar baja galvanis
Kabel di tangan kanan berbaring.
Konstruksi Parameter
IEC 60502 6.35/11 kV ABC untuk Overhead Jalur Distribusi
Jumlah Core XNominal Cross Section |
Konduktor fase |
Messenger Suspensi Unit |
Terus menerus |
||||
Terdampar | Nominal Sectional Area | Maksimum Konduktor Resistance |
Terdampar | Nominal Sectional Area | Melanggar Memuat |
||
Tidak, ×mm² | Tidak, ×mm | Mm² | ω/Km | Tidak, ×mm | Mm² | KN | Yang |
3X50 + 1X25 | 19/1 78 | 50 | 0.641 | 7/3. 0 | 50 | 60 | 116 |
3X70 + 1X50 | 19/14 | 70 | 0.443 | 8/7/3 | 50 | 62 | 210 |
3X95 + 1X50 | 19/2 52 | 95 | 0.32 | 7/3. 0 | 50 | 60 | 173 |
3X185 + 1X120 | 37/2 52 | 185 | 0.164 | 7/4 67 | 120 | 150 | 259 |
3X150 + 1X50 | 37/2 25 | 150 | 0.206 | 8/7/3 | 50 | 62 | 365 |
3X240 + 1X50 | 61/2 25 | 240 | 0.125 | 8/7/3 | 50 | 62 | 500 |
Lain bagian lintas dapat ditawarkan berdasarkan permintaan.
IEC 60502 19/33 kV ABC untuk Overhead Jalur Distribusi
Jumlah Core XNominal Cross Section |
Konduktor fase |
Messenger Suspensi Unit |
Terus menerus |
||||
Terdampar | Nominal Sectional Area | Maksimum Konduktor Resistance |
Terdampar | Nominal Sectional Area | Melanggar Memuat |
||
Tidak, ×mm² | Tidak, ×mm | Mm² | ω/Km | Tidak, ×mm | Mm² | KN | Yang |
3X50 + 1X50 | 19/1 78 | 50 | 0.641 | 7/3. 0 | 50 | 60 | 165 |
3X150 + 1X50 | 37/2 25 | 150 | 0.206 | 7/3. 0 | 50 | 60 | 315 |
3X185 + 1X70 | 37/2 52 | 185 | 0.164 | 7/3 57 | 70 | 91 | 355 |
3X70 + 1X50 | 19/2 14 | 7 | 0.443 | 8/7/3 | 50 | 62 | 250 |
3X150 + 1X50 | 37/2 25 | 150 | 0.206 | 8/7/3 | 50 | 62 | 370 |
Lain bagian lintas dapat ditawarkan berdasarkan permintaan.
AS/NZS 3599 Bagian 1 6.35/11 kV AL/XLPE/HDPE Tidak disaring Kabel
Jumlah Core XNominal Cross Section |
Konduktor fase |
Messenger Suspensi Unit |
Nominal Sectional Area |
Melanggar |
|||
Diameter Dari Konduktor |
Ketebalan Dari Isolasi |
Ketebalan Dari Isolasi Layar |
Ketebalan Dari Di atas lutut |
Terdampar | |||
Tidak, ×mm² | Mm | Mm | Mm | Mm | Tidak, ×mm | Mm² | KN |
3×35 | 6.9 | 3.4 | 0.8 | 1.2 | 7/4 75 | 52.4 | 1370 |
3×50 | 8.1 | 3.4 | 0.8 | 1.2 | 7/4 75 | 54.6 | 1530 |
3×70 | 9.7 | 3.4 | 0.8 | 1.2 | 7/4 75 | 57.8 | 1790 |
3×95 | 11.4 | 3.4 | 0.8 | 1.2 | 7/4 75 | 61.3 | 2100 |
3×120 | 12.8 | 3.4 | 0.8 | 1.2 | 19/3, 50 | 67.3 | 2540 |
3×150 | 14.2 | 3.4 | 0.8 | 1.2 | 19/3, 50 | 70.1 | 2840 |
3×185 | 15.7 | 3.4 | 0.8 | 1.2 | 19/3, 50 | 73.1 | 3190 |
Lain bagian lintas dapat ditawarkan berdasarkan permintaan.
AS/NZS 3599 Bagian 1 6.35/11 kV AL/XLPE/CWS/HDPE Disaring Kabel
Jumlah Core XNominal Cross Section |
Diameter Dari Konduktor |
Ketebalan Dari Isolasi |
Ketebalan Dari Isolasi Layar |
Tembaga Kawat Terdampar | Ketebalan Dari Di atas lutut |
Kawat Baja galvanis Terdampar | Nominal Sectional Area | Melanggar Memuat |
Tidak, ×mm² | Mm | Mm | Mm | Tidak, ×mm | Mm | Tidak, ×mm | Mm² | KN |
Light Duty Layar |
||||||||
3×35 | 6.9 | 3.4 | 0.8 | 25/0 85 | 1.8 | 7/2. 00 | 54.1 | 1820 |
3×35 | 6.9 | 3.4 | 0.8 | 25/0 85 | 1.8 | 19/2. 00 | 58.1 | 2130 |
3×50 | 8.1 | 3.4 | 0.8 | 25/0 85 | 1.8 | 19/2. 00 | 60.4 | 2300 |
3×70 | 9.7 | 3.4 | 0.8 | 25/0 85 | 1.8 | 19/2. 00 | 63.6 | 2570 |
3×95 | 11.4 | 3.4 | 0.8 | 25/0 85 | 1.8 | 19/2. 00 | 67.0 | 2900 |
3×120 | 12.8 | 3.4 | 0.8 | 25/0 85 | 1.8 | 19/2. 00 | 69.8 | 3190 |
3×150 | 14.2 | 3.4 | 0.8 | 25/0 85 | 1.9 | 19/2. 00 | 73.0 | 3530 |
3×185 | 15.7 | 3.4 | 0.8 | 25/0 85 | 1.9 | 19/2. 00 | 76.0 | 3890 |
Tugas berat Layar |
||||||||
3×35 | 6.9 | 3.4 | 0.8 | 40/0 85 | 1.8 | 7/2. 00 | 54.1 | 2050 |
3×35 | 6.9 | 3.4 | 0.8 | 40/0 85 | 1.8 | 19/2. 00 | 58.1 | 2360 |
3×50 | 8.1 | 3.4 | 0.8 | 23/1 35 | 1.8 | 19/2. 00 | 62.4 | 2820 |
3×70 | 9.7 | 3.4 | 0.8 | 32/1 35 | 1.8 | 19/2. 00 | 65.6 | 3440 |
3×95 | 11.4 | 3.4 | 0.8 | 39/1 35 | 1.8 | 19/2. 00 | 69.0 | 4030 |
3×120 | 12.8 | 3.4 | 0.8 | 39/1 35 | 1.8 | 19/2. 00 | 71.8 | 4320 |
3×150 | 14.2 | 3.4 | 0.8 | 39/1 35 | 1.9 | 19/2. 00 | 75.0 | 4670 |
3×185 | 15.7 | 3.4 | 0.8 | 39/1 35 | 1.9 | 19/2. 00 | 78.0 | 5020 |
Lain bagian lintas dapat ditawarkan berdasarkan permintaan.
AS/NZS 3599 Bagian 1 12.7/22 kV AL/XLPE/HDPE Tidak disaring Kabel
Jumlah Core XNominal Cross Section |
Konduktor fase |
Messenger Suspensi Unit |
Nominal Sectional Area |
Melanggar |
|||
Diameter Dari Konduktor |
Ketebalan Dari Isolasi |
Ketebalan Dari Isolasi Layar |
Ketebalan Dari Di atas lutut |
Terdampar | |||
Tidak, ×mm² | Mm | Mm | Mm | Mm | Tidak, ×mm | Mm² | KN |
3×35 | 6.9 | 5.5 | 0.8 | 1.2 | 7/4 75 | 61.0 | 1780 |
3×50 | 8.1 | 5.5 | 0.8 | 1.2 | 7/4 75 | 63.3 | 1970 |
3×70 | 9.7 | 5.5 | 0.8 | 1.2 | 7/4 75 | 66.5 | 2260 |
3×95 | 11.4 | 5.5 | 0.8 | 1.2 | 7/4 75 | 69.9 | 2600 |
3×120 | 12.8 | 5.5 | 0.8 | 1.2 | 19/3, 50 | 75.9 | 3070 |
3×150 | 14.2 | 5.5 | 0.8 | 1.2 | 19/3, 50 | 78.7 | 3390 |
3×185 | 15.7 | 5.5 | 0.8 | 1.2 | 19/3, 50 | 81.7 | 3760 |
Lain bagian lintas dapat ditawarkan berdasarkan permintaan.
AS/NZS 3599 Bagian 1 12.7/22 kV AL/XLPE/CWS/HDPE Disaring Kabel
Jumlah Core XNominal Cross Section |
Diameter Dari Konduktor |
Ketebalan Dari Isolasi |
Ketebalan Dari Isolasi Layar |
Tembaga Kawat Terdampar | Ketebalan Dari Di atas lutut |
Kawat Baja galvanis Terdampar | Nominal Sectional Area | Melanggar Memuat |
Tidak, ×mm² | Mm | Mm | Mm | Tidak, ×mm | Mm | Tidak, ×mm | Mm² | KN |
Light Duty Layar |
||||||||
3×35 | 6.9 | 5.5 | 0.8 | 25/0 85 | 1.8 | 7/2. 00 | 62.7 | 2280 |
3×35 | 6.9 | 5.5 | 0.8 | 25/0 85 | 1.8 | 19/2. 00 | 66.7 | 2580 |
3×50 | 8.1 | 5.5 | 0.8 | 25/0 85 | 1.8 | 19/2. 00 | 69.0 | 2780 |
3×70 | 9.7 | 5.5 | 0.8 | 25/0 85 | 1.9 | 19/2. 00 | 72.6 | 3110 |
3×95 | 11.4 | 5.5 | 0.8 | 25/0 85 | 1.9 | 19/2. 00 | 76.0 | 3460 |
3×120 | 12.8 | 5.5 | 0.8 | 25/0 85 | 2.0 | 19/2. 00 | 79.2 | 3810 |
3×150 | 14.2 | 5.5 | 1.0 | 25/0 85 | 2.0 | 19/2. 00 | 82.8 | 4230 |
3×185 | 15.7 | 5.5 | 1.0 | 25/0 85 | 2.1 | 19/2. 00 | 86.2 | 4650 |
Tugas berat Layar |
||||||||
3×35 | 6.9 | 5.5 | 0.8 | 40/0 85 | 1.8 | 7/2. 00 | 62.7 | 2510 |
3×35 | 6.9 | 5.5 | 0.8 | 40/0 85 | 1.8 | 19/2. 00 | 66.7 | 2810 |
3×50 | 8.1 | 5.5 | 0.8 | 23/1 35 | 1.8 | 19/2. 00 | 71.0 | 3300 |
3×70 | 9.7 | 5.5 | 0.8 | 32/1 35 | 1.9 | 19/2. 00 | 74.6 | 3970 |
3×95 | 11.4 | 5.5 | 0.8 | 39/1 35 | 1.9 | 19/2. 00 | 78.0 | 4600 |
3×120 | 12.8 | 5.5 | 0.8 | 39/1 35 | 2.0 | 19/2. 00 | 81.2 | 4950 |
3×150 | 14.2 | 5.5 | 1.0 | 39/1 35 | 2.0 | 19/2. 00 | 84.8 | 5360 |
3×185 | 15.7 | 5.5 | 1.0 | 39/1 35 | 2.1 | 19/2. 00 | 88.2 | 5790 |
Lain bagian lintas dapat ditawarkan berdasarkan permintaan.
Data teknis
Nominal Cross Section |
Terus menerus Peringkat Saat Ini |
||
Masih air | 1 m/s angin | 2 m/s angin | |
Mm² | Yang | Yang | Yang |
35 | 105 | 145 | 165 |
50 | 125 | 170 | 200 |
70 | 150 | 215 | 250 |
95 | 180 | 260 | 300 |
120 | 205 | 300 | 350 |
150 | 230 | 340 | 395 |
185 | 265 | 390 | 450 |
Lain bagian lintas dapat ditawarkan berdasarkan permintaan.
Quadruplex Layanan Drop-Konduktor Aluminium
Aplikasi
Digunakan sebagai overhead kabel pasokan 3-phase power, biasanya dari tiang dipasang transformator, untuk pengguna layanan kepala di mana koneksi ke layanan kabel masuk dibuat. Untuk digunakan pada tegangan 600 volt phase-To-phase atau kurang dan di konduktor suhu tidak untuk melebihi 75 °C untuk polyethylene konduktor terisolasi atau 90 °C untuk cross linked polyethylene (XLPE) konduktor terisolasi.
Triplex layanan drop-Konduktor aluminium
Aplikasi
Digunakan sebagai overhead kabel untuk power supply, biasanya dari tiang dipasang transformator, untuk pengguna layanan kepala di mana koneksi ke layanan kabel masuk dibuat. Untuk digunakan pada tegangan 600 volt phase-To-phase atau kurang dan di konduktor suhu tidak untuk melebihi 75 °C untuk polyethylene konduktor terisolasi atau 90 °C untuk cross linked polyethylene (XLPE) konduktor terisolasi.
Duplex Layanan Drop-Konduktor Aluminium
Aplikasi
Terutama digunakan sebagai overhead kabel atau udara kabel untuk 120 volt overhead aplikasi layanan seperti penerangan lampu outdoor dan sementara layanan untuk konstruksi. Untuk digunakan pada tegangan 600 volt phase-To-phase atau kurang dan di konduktor suhu tidak untuk melebihi 75 °C untuk polyethylene konduktor terisolasi atau 90 °C untuk cross linked polyethylene (XLPE) konduktor terisolasi.
1. Kami memiliki besar basis produksi dan peralatan produksi yang maju
2. memiliki harga yang kompetitif dan kualitas tinggi
3. layanan purna jual yang sangat baik
4. desain yang menarik dan berbagai gaya
5. Masalah gratis: kemasan daftar faktur, CD instalasi
6. teknologi yang kuat R & D tim
7. Sistem jaminan kualitas yang ketat dan pengujian yang sempurna berarti
8. Peralatan proses Lanjutan
9. Dilukis dengan kuatAntiseptik Anticorrosion bahanCat
10. pengiriman tepat waktu
11. Roller coaster kami penjualan untuk Timur Tengah, Afrika, Rusia, Asia Tenggara, dll.
12. Kami memiliki reputasi yang baik di luar negeri
Informasi Kontak
Jika Anda tidak dapat menemukan produk yang Anda butuhkan dalam daftar, silahkan hubungi saya, dan Aku akan melayani Anda dengan sepenuh hati!!!
Kami berharap untuk pertanyaan Anda dan bagus cooperaton.
- Next: Low Voltage aluminum / copper 4 core 10mm2 16mm2 25mm2 45mm2 50mm2 75mm2 copper electrical wire ground cable
- Previous: Different acsr standards Steel Reinforced acsr dog conductor price with acsr cable transmission line