Tegangan rendah 0.6/1kv layanan udara konsentris abc kabel (kabel bundel udara) triplex layanan drop cable untuk 600 v
Pelabuhan: | Qingdao port for triplex service drop cable |
Ketentuan Pembayaran: | L/C,T/T,Western Union,MoneyGram |
Kemampuan Pasokan: | 1600 Kilometer/kilometer per Month triplex layanan drop kabel |
Tempat asal: | Henan Cina |
Nama merek: | Hongda triplex layanan drop kabel |
Nomor model: | triplex layanan drop kabel |
Bahan isolasi: | tidak ada isolasi |
Jenis: | Tegangan Rendah |
Aplikasi: | Overhead |
Bahan konduktor: | Aluminium |
Jaket: | tidak ada selubung |
bahan: | paduan aluminium |
Mark: | CCC, IEC |
standar: | AWG, IEC, BS, ASTM |
menggunakan: | Overhead, jalur transmisi listrik |
Jenis kabel: | triplex layanan drop kabel |
Jenis konduktor: | AAC AAAC ACSR ACAR |
tegangan: | 600/1000 Volt |
isolasi: | XLPE Isolasi |
Packing: | kayu Drum |
Core: | multi-core |
Perincian Pengiriman: | dikirim dalam 15 hari setelah pembayaran |
Perincian Pengemasan: | standar ekspor kayu drum setiap akhir kabel harus tegas dan dijamin benar untuk drum untuk triplex layanan drop kabel |
600 VOLT SEKUNDER UD-DUPLEX/TRIPLEX/QUADRUPLEX
APLIKASI
langsung dimakamkan atau dipasang di saluran untuk 600 volt distribusi sekunder.
FITUR PRODUK
konsentris terdampar atau terkompresi 1350-H19 aluminium konduktor, isolasi polietilen silang. konduktor terisolasi permukaan dicetak, netral, tiga yellow striped atau padat kuning. hitam netral dapat ditentukan jika diinginkan.
STANDAR
ASTM B-230, B-231 amd ICEA S-105-692 UL Standar 854 untuk Jenis USE-2
Spesifikasi Federal JC-30B NEC
HONGDA KABEL Duplex Kabel Konduktor 600 Volt Sekunder Jenis URD-Aluminium Konduktor |
|||||||||||
Kata kode |
fase Konduktor |
Konduktor netral |
tunggal |
di luar |
berat |
Ampacity |
|||||
ukuran |
Strand |
Ketebalan isolasi |
ukuran |
Strand |
Ketebalan isolasi |
Penguburan langsung |
dalam Saluran |
||||
Bard |
8 |
7/W |
60 |
8 |
7/W |
60 |
. 262 |
. 524 |
76 |
70 |
55 |
Clafin |
6 |
7/W |
60 |
6 |
7/W |
60 |
. 299 |
. 596 |
91 |
95 |
70 |
Delgado |
4 |
7/W |
60 |
4 |
7/W |
60 |
. 345 |
. 690 |
129 |
125 |
90 |
Everett |
2 |
7/W |
60 |
2 |
7/W |
60 |
. 403 |
. 808 |
187 |
187 |
100 |
HONGDA KABEL Triplex Kabel Konduktor 600 Volt Sekunder Jenis URD-Aluminium Konduktor |
|||||||||||
Kata kode |
fase Konduktor |
Konduktor netral |
tunggal |
di luar |
berat |
Ampacity |
|||||
ukuran |
Strand |
Ketebalan isolasi |
ukuran |
Strand |
Ketebalan isolasi |
Penguburan langsung |
dalam Saluran |
||||
Erksine |
6 |
7/w |
60 |
6 |
7/w |
60 |
. 299 |
. 646 |
143 |
95 |
70 |
Vassar |
4 |
7/w |
60 |
4 |
7/w |
60 |
. 345 |
. 754 |
203 |
125 |
90 |
Stephens |
2 |
7/w |
60 |
4 |
7/w |
60 |
. 403 |
. 842 |
264 |
165 |
120 |
Ramapo |
2 |
7/w |
60 |
2 |
7/w |
60 |
. 403 |
. 874 |
294 |
165 |
120 |
Brenau |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
. 522 |
1.064 |
408 |
215 |
160 |
Bergen |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
. 522 |
1.133 |
465 |
215 |
160 |
Converse |
2/0 |
19/w |
80 |
1 |
19/w |
80 |
. 566 |
1.174 |
502 |
245 |
180 |
Hunter |
2/0 |
19/w |
80 |
2/0 |
19/w |
80 |
. 566 |
1.228 |
560 |
245 |
180 |
Hollins |
3/0 |
19/w |
80 |
1/0 |
19/w |
80 |
. 616 |
1.276 |
606 |
280 |
205 |
Sweetbriar |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
. 672 |
1.389 |
739 |
315 |
240 |
Monmouth |
4/0 |
19/w |
80 |
4/0 |
19/w |
80 |
. 672 |
1.457 |
828 |
315 |
240 |
Pratt |
250 |
37/w |
95 |
3/0 |
19/w |
80 |
. 748 |
1.538 |
893 |
345 |
265 |
Wesleyan |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
. 851 |
1.736 |
1166 |
415 |
320 |
Rider |
500 |
37/w |
95 |
350 |
37/w |
95 |
. 979 |
2.035 |
1663 |
495 |
395 |
Fairfield |
750 |
61/w |
110 |
500 |
37/w |
95 |
1.118 |
2.860 |
2304 |
615 |
525 |
HONGDA KABEL Quadruplex Kabel Konduktor 600 Volt Sekunder Jenis URD-Aluminium Konduktor |
|||||||||||
Kata kode |
fase Konduktor |
Konduktor netral |
tunggal |
di luar |
berat |
Ampacity |
|||||
ukuran |
Strand |
Ketebalan isolasi |
ukuran |
Strand |
Ketebalan isolasi |
Penguburan langsung |
dalam Saluran |
||||
Tulsa |
4 |
7/w |
60 |
4 |
7/w |
60 |
. 345 |
. 833 |
258 |
119 |
85 |
Dyke |
2 |
7/w |
60 |
4 |
7/w |
60 |
. 403 |
. 938 |
346 |
153 |
115 |
Wittenberg |
2 |
7/w |
60 |
2 |
7/w |
60 |
. 403 |
. 973 |
375 |
153 |
115 |
Notre Dame |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
. 522 |
1.188 |
541 |
198 |
150 |
Purdue |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
. 522 |
1.260 |
596 |
198 |
150 |
Syracuse |
2/0 |
19/w |
80 |
1 |
19/w |
80 |
. 566 |
1.316 |
664 |
225 |
170 |
Wake Forest |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
. 672 |
1.560 |
979 |
290 |
225 |
karat |
250 |
37/w |
95 |
3/0 |
19/w |
80 |
. 748 |
1.725 |
1,176 |
319 |
240 |
licin Batu |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
. 851 |
1.945 |
1,544 |
385 |
305 |
Wofford |
500 |
37/w |
95 |
350 |
37/w |
95 |
. 851 |
2.348 |
2,174 |
467 |
420 |
Westminster |
750 |
61/w |
110 |
350 |
37/w |
95 |
. 979 |
2.722 |
2,816 |
615 |
492 |
Ampacity: 90 ° C suhu konduktor, 20 ° C ambient, RHO 90, 100% beban faktor untuk tiga konduktor triplex dengan netral membawa hanya beban tidak seimbang.
semua Kuning Diekstrusi Stripe, kabel adalah XLP isolasi.
* untuk menentukan benar ampacity oleh konduktor ukuran, silakan berkonsultasi Kode Listrik Nasional, edisi terbaru.
data di atas adalah perkiraan dan tunduk pada normal toleransi manufaktur.
lintas-bagian lainnya dapat ditawarkan atas permintaan.
Quadruplex Layanan Drop-Aluminium Konduktor
aplikasi
digunakan sebagai kabel overhead untuk supply 3-phase power, biasanya dari tiang-mount transformator, pengguna layanan kepala di mana koneksi ke pintu masuk layanan kabel dibuat. untuk digunakan pada tegangan dari 600 volt fase-untuk fase atau kurang dan pada konduktor suhu tidak melebihi 75 ° C untuk polyethylene konduktor terisolasi atau 90 ° C untuk cross-linked polyethylene (XLPE) konduktor terisolasi.
Triplex layanan drop-aluminium Konduktor
aplikasi
digunakan sebagai kabel overhead untuk memasok listrik, biasanya dari tiang-mount transformator, pengguna layanan kepala di mana koneksi ke pintu masuk layanan kabel dibuat. untuk digunakan pada tegangan dari 600 volt fase-untuk fase atau kurang dan pada konduktor suhu tidak melebihi 75 ° C untuk polyethylene konduktor terisolasi atau 90 ° C untuk cross-linked polyethylene (XLPE) konduktor terisolasi.
Layanan Duplex Drop-Aluminium Konduktor
aplikasi
terutama digunakan sebagai kabel atau kabel untuk 120 volt udara overhead overhead layanan aplikasi seperti jalan pencahayaan, luar pencahayaan, dan layanan sementara untuk konstruksi. untuk digunakan pada tegangan dari 600 volt fase-untuk fase atau kurang dan pada konduktor suhu tidak melebihi 75 ° C untuk polyethylene konduktor terisolasi atau 90 ° C untuk cross-linked polyethylene (XLPE) konduktor terisolasi.
1. Kami memiliki basis produksi yang besar, dan peralatan produksi yang maju
2. memiliki harga yang kompetitif dan kualitas tinggi
3. Excellent layanan purna jual
4. desain Yang Menarik dan berbagai gaya
5. masalah Gratis: kemasan daftar, faktur, CD instalasi
6. teknologi R & D tim Yang Kuat
7. sistem jaminan kualitas Yang Ketat dan pengujian yang sempurna berarti
8. peralatan proses Lanjutan
9. Painted dengan kuatantiseptik bahan Anticorrosioncat
10. Pengiriman tepat waktu
11. roller coaster penjualan kami untuk Timur Tengah, Afrika, Rusia, Asia Tenggara, dll.
12. Kami memiliki reputasi yang baik di luar negeri
informasi kontak
jika anda tidak dapat menemukan produk yang anda butuhkan dalam daftar, silahkan hubungi saya, dan Saya akan melayani untuk anda sepenuh hati!!!
kami berharap untuk pertanyaan anda dan bagus cooperaton.
- Next: 600 Volts 1c XHHW-2 conductors 2core / 4 core 2.5mm 4mm 6mm 10mm 16mm PVC jacket / insulated power cable
- Previous: LV – 240mm2 185mm2 150mm2 120mm2 95mm2 70mm2 Aerial Bundled Conductor Aluminum Covered Line Wire