Tegangan rendah 0.6/1kv 600 V Quadruplex Aluminium Konduktor kabel URD
Pelabuhan: | Qingdao port for quadruplex service drop cable |
Ketentuan Pembayaran: | L/C,T/T,Western Union,MoneyGram |
Kemampuan Pasokan: | 3200 Kilometer/kilometer per Month layanan quadruplex penurunan kabel |
Tempat asal: | Henan Cina |
Nama merek: | Hongda bare conductor |
Nomor model: | Quadruplex layanan drop cable |
Bahan isolasi: | Tidak ada isolasi |
Jenis: | Tegangan Rendah |
Aplikasi: | Overhead |
Bahan konduktor: | Aluminium |
Jaket: | Tidak ada di atas lutut |
Bahan: | Paduan aluminium |
Mark: | CCC IEC |
Standar: | AWG, IEC, BS ASTM |
Menggunakan: | Overhead, transmisi tenaga listrik |
Jenis kabel: | Quadruplex layanan drop cable |
Tipe konduktor: | ACSR AAC AAAC ACAR |
Perincian Pengemasan: | standar ekspor kayu drum setiap akhir kabel harus tegas dan dijamin benar untuk drum untuk layanan quadruplex penurunan kabel |
600 VOLT SEKUNDER UD DUPLEX/TRIPLEX/QUAINT
APLIKASI
Ini diatas terkubur atau dipasang di saluran untuk 600 volt distribusi sekunder.
FITUR PRODUK
Konsentris terdampar atau terkompresi 1350-H19 aluminium konduktor, crosslinked polyethylene isolasi. Konduktor terisolasi permukaan dicetak, atau netral mengenai saham triple kuning bergaris atau padat kuning. Hitam netral dapat ditentukan jika diinginkan.
STANDAR
ASTM B-230, B-231 amd ICEA S-105-692 Standar UL 854 untuk Tipe MENGGUNAKAN-2
Federal Spesifikasi JC-30B NEC
HONGDA KABEL Duplex Konduktor 600 Volt Tipe Sekunder URD Kabel Konduktor Aluminium |
|||||||||||
Kode |
Konduktor-konduktor fasa |
Penghantar netral |
Single |
Di luar |
Berat |
Ampacity |
|||||
Ukuran |
Strand |
Isolasi Ketebalan |
Ukuran |
Strand |
Isolasi Ketebalan |
Penguburan langsung |
Di Saluran |
||||
Bard |
8 |
7/W |
60 |
8 |
7/W |
60 |
262 |
524 |
76 |
70 |
55 |
Clafin |
6 |
7/W |
60 |
6 |
7/W |
60 |
299 |
596 |
91 |
95 |
70 |
Delgado |
4 |
7/W |
60 |
4 |
7/W |
60 |
345 |
690 |
129 |
125 |
90 |
Everett |
2 |
7/W |
60 |
2 |
7/W |
60 |
403 |
808 |
187 |
187 |
100 |
HONGDA KABEL Triplex Konduktor 600 Volt Tipe Sekunder URD Kabel Konduktor Aluminium |
|||||||||||
Kode |
Konduktor-konduktor fasa |
Penghantar netral |
Single |
Di luar |
Berat |
Ampacity |
|||||
Ukuran |
Strand |
Isolasi Ketebalan |
Ukuran |
Strand |
Isolasi Ketebalan |
Penguburan langsung |
Di Saluran |
||||
Erksine |
6 |
7/w |
60 |
6 |
7/w |
60 |
299 |
646 |
143 |
95 |
70 |
Vassar |
4 |
7/w |
60 |
4 |
7/w |
60 |
345 |
754 |
203 |
125 |
90 |
Stephens |
2 |
7/w |
60 |
4 |
7/w |
60 |
403 |
842 |
264 |
165 |
120 |
Ramapo |
2 |
7/w |
60 |
2 |
7/w |
60 |
403 |
874 |
294 |
165 |
120 |
Brenau |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
522 |
1.064 |
408 |
215 |
160 |
Bergen |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
522 |
1.133 |
465 |
215 |
160 |
Converse |
2/0 |
19/w |
80 |
1 |
19/w |
80 |
566 |
1.174 |
502 |
245 |
180 |
Hunter |
2/0 |
19/w |
80 |
2/0 |
19/w |
80 |
566 |
1.228 |
560 |
245 |
180 |
Hollins |
3/0 |
19/w |
80 |
1/0 |
19/w |
80 |
616 |
1.276 |
606 |
280 |
205 |
Sweetbriar |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
672 |
1.389 |
739 |
315 |
240 |
Monmouth |
4/0 |
19/w |
80 |
4/0 |
19/w |
80 |
672 |
1.457 |
828 |
315 |
240 |
Pratt |
250 |
37/w |
95 |
3/0 |
19/w |
80 |
748 |
1.538 |
893 |
345 |
265 |
Wesleyan |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
851 |
1.736 |
1166 |
415 |
320 |
Rider |
500 |
37/w |
95 |
350 |
37/w |
95 |
979 |
2.035 |
1663 |
495 |
395 |
Fairfield |
750 |
61/w |
110 |
500 |
37/w |
95 |
1.118 |
2.860 |
2304 |
615 |
525 |
HONGDA KABEL Quaint Konduktor 600 Volt Tipe Sekunder URD Kabel Konduktor Aluminium |
|||||||||||
Kode |
Konduktor-konduktor fasa |
Penghantar netral |
Single |
Di luar |
Berat |
Ampacity |
|||||
Ukuran |
Strand |
Isolasi Ketebalan |
Ukuran |
Strand |
Isolasi Ketebalan |
Penguburan langsung |
Di Saluran |
||||
Tulsa |
4 |
7/w |
60 |
4 |
7/w |
60 |
345 |
833 |
258 |
119 |
85 |
Dyke |
2 |
7/w |
60 |
4 |
7/w |
60 |
403 |
938 |
346 |
153 |
115 |
Wittenberg |
2 |
7/w |
60 |
2 |
7/w |
60 |
403 |
973 |
375 |
153 |
115 |
Notre Dame |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
522 |
1.188 |
541 |
198 |
150 |
Purdue |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
522 |
1.260 |
596 |
198 |
150 |
Syracuse |
2/0 |
19/w |
80 |
1 |
19/w |
80 |
566 |
1.316 |
664 |
225 |
170 |
Wake Forest |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
672 |
1.560 |
979 |
290 |
225 |
Karat |
250 |
37/w |
95 |
3/0 |
19/w |
80 |
748 |
1.725 |
1,176 |
319 |
240 |
Slippery Rock |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
851 |
1.945 |
1,544 |
385 |
305 |
Wofford |
500 |
37/w |
95 |
350 |
37/w |
95 |
851 |
2.348 |
2,174 |
467 |
420 |
Westminster |
750 |
61/w |
110 |
350 |
37/w |
95 |
979 |
2.722 |
2,816 |
615 |
492 |
Ampacity: 90 °C konduktor suhu 20 °C ambient, RHO 90, 100% faktor beban untuk tiga konduktor triplex netral membawa hanya tidak seimbang beban.
Semua Kuning Ekstrusi Garis, kabel XLP isolasi.
* Untuk yang benar ampacity dengan ukuran konduktor, silakan berkonsultasi dengan Listrik Nasional Kode edisi terbaru.
Di atas adalah perkiraan dan normal toleransi manufaktur.
Lain bagian lintas dapat ditawarkan berdasarkan permintaan.
Quadruplex Layanan Drop-Konduktor Aluminium
Aplikasi
Digunakan sebagai overhead kabel pasokan 3-phase power, biasanya dari tiang dipasang transformator, untuk pengguna layanan kepala di mana koneksi ke layanan kabel masuk dibuat. Untuk digunakan pada tegangan 600 volt phase-To-phase atau kurang dan di konduktor suhu tidak untuk melebihi 75 °C untuk polyethylene konduktor terisolasi atau 90 °C untuk cross linked polyethylene (XLPE) konduktor terisolasi.
Triplex layanan drop-Konduktor aluminium
Aplikasi
Digunakan sebagai overhead kabel untuk power supply, biasanya dari tiang dipasang transformator, untuk pengguna layanan kepala di mana koneksi ke layanan kabel masuk dibuat. Untuk digunakan pada tegangan 600 volt phase-To-phase atau kurang dan di konduktor suhu tidak untuk melebihi 75 °C untuk polyethylene konduktor terisolasi atau 90 °C untuk cross linked polyethylene (XLPE) konduktor terisolasi.
Duplex Layanan Drop-Konduktor Aluminium
Aplikasi
Terutama digunakan sebagai overhead kabel atau udara kabel untuk 120 volt overhead aplikasi layanan seperti penerangan lampu outdoor dan sementara layanan untuk konstruksi. Untuk digunakan pada tegangan 600 volt phase-To-phase atau kurang dan di konduktor suhu tidak untuk melebihi 75 °C untuk polyethylene konduktor terisolasi atau 90 °C untuk cross linked polyethylene (XLPE) konduktor terisolasi.
1. Kami memiliki besar basis produksi dan peralatan produksi yang maju
2. memiliki harga yang kompetitif dan kualitas tinggi
3. layanan purna jual yang sangat baik
4. desain yang menarik dan berbagai gaya
5. Masalah gratis: kemasan daftar faktur, CD instalasi
6. teknologi yang kuat R & D tim
7. Sistem jaminan kualitas yang ketat dan pengujian yang sempurna berarti
8. Peralatan proses Lanjutan
9. Dilukis dengan kuatAntiseptik Anticorrosion bahanCat
10. pengiriman tepat waktu
11. Roller coaster kami penjualan untuk Timur Tengah, Afrika, Rusia, Asia Tenggara, dll.
12. Kami memiliki reputasi yang baik di luar negeri
Informasi Kontak
Jika Anda tidak dapat menemukan produk yang Anda butuhkan dalam daftar, silahkan hubungi saya, dan Aku akan melayani Anda dengan sepenuh hati!!!
Kami berharap untuk pertanyaan Anda dan bagus cooperaton.
- Next: XLPE or PE insulated 600 volt secondary distribution 16sq mm aluminum cable single core overhead abc power cable
- Previous: 600 / 1000 volts 3x70mm2 1×54.6mm2 1x16mm2 abc cable with NF C 33-209 aerial bundled cable