aluminium lapis baja kabel
Pelabuhan: | China Main Port |
Ketentuan Pembayaran: | L/C,D/P,T/T |
Kemampuan Pasokan: | 500 Kilometer/kilometer per Month |
Tempat asal: | Henan Cina |
Nama merek: | Jinshui |
Nomor model: | 4*185mm2 |
Bahan isolasi: | PVC |
Jenis: | Tegangan Rendah |
Aplikasi: | Bawah Tanah |
Bahan konduktor: | Aluminium |
Jaket: | PVC |
bahan: | aluminium |
Perincian Pengiriman: | setelah menerima deposito 10-20days |
Perincian Pengemasan: | kayu Drum , besi kayu Drum |
Specifications
1 Conductor:Copper or Aluminium
2 Insulation:PVC
3 Voltage:Low Voltage
4 Standard:IEC 60502,GB/T 12706
Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)
4). Voltage:0.6/1kV,
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers' requirements
7). Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2,
240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2.
Type |
Designation |
Applications |
|
VV YJV VLV YJLV |
Copper conductor, PVC ,XLPE insulated, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, PVC sheathed power cable |
For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct. |
|
VY YJY VLY YJLY |
Copper conductor, PVC,XLPE insulated, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, PE sheathed power cable |
||
VV22 YJV22 VLV22 YJLV22 |
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable |
For laying indoors, in tunnel, in cable trench or direct in ground, a ble to bear external mechanical forces, but unable to bear large pulling force. |
|
VV23 YJV23 VLV23 YJLV23 |
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable |
||
VV32 YJV32 VLV32 YJLV32 |
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable |
For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
|
VV33 YJV33 VLV33 YJLV33 |
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable |
||
Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied. |