aluminium lapis baja kabel

aluminium lapis baja kabel
Pelabuhan: China Main Port
Ketentuan Pembayaran: L/C,D/P,T/T
Kemampuan Pasokan: 500 Kilometer/kilometer per Month
Tempat asal: Henan Cina
Nama merek: Jinshui
Nomor model: 4*185mm2
Bahan isolasi: PVC
Jenis: Tegangan Rendah
Aplikasi: Bawah Tanah
Bahan konduktor: Aluminium
Jaket: PVC
bahan: aluminium
Perincian Pengiriman: setelah menerima deposito 10-20days
Perincian Pengemasan: kayu Drum , besi kayu Drum

Specifications

1 Conductor:Copper or Aluminium
2 Insulation:PVC 
3 Voltage:Low Voltage
4 Standard:IEC 60502,GB/T 12706

 Technical Parameters of our Power Cable 

1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890

2). Detailed description or construction:

    * Conductor: compacted or uncompacted copper or aluminium

    * Insulation: Polyvinyl chloride (PVC)

    * Filler: Polypropylene filament with lapped binding tape

    * Binder: Binding tape

    * Inner sheath: Polyvinyl chloride (PVC)

    * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)

    *Sheath: Polyvinyl chloride (PVC)

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

    U0/U(Um) =0.6/1(1.2)

4). Voltage:0.6/1kV, 

    In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.

5). Application:

     For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

6). Marking: According to the customers' requirements

7). Nominal cross-sectional areas:

1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 

240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2.

 

Type

Designation

Applications

VV

YJV

VLV

YJLV

Copper conductor, PVC ,XLPE insulated, PVC sheathed power cable

Aluminium conductor, PVC ,XLPE  insulated, PVC sheathed power cable

For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct.

VY

YJY

VLY

YJLY

Copper conductor, PVC,XLPE insulated, PE sheathed power cable

Aluminium conductor, PVC ,XLPE insulated, PE sheathed power cable

VV22

YJV22

VLV22

YJLV22

Copper conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable

Aluminium conductor, PVC ,XLPE  insulated, steel tape armoured, PVC sheathed power cable

For laying indoors, in tunnel, in cable trench or direct in ground, a

ble to bear external mechanical forces, but unable to bear large pulling force.

VV23

YJV23

VLV23

YJLV23

Copper conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable

Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable

VV32

YJV32

VLV32

YJLV32

Copper conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable

Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable

For laying indoors, in tunnel, in cable trench or direct in ground, 

able to bear external mechanical forces, but unable to bear large pulling force.

VV33

YJV33

VLV33

YJLV33

Copper conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable

Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable

Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied.

 

 

 

Tags: ,

Contact us

 

 

 