0.6/LV 1KV overhead AAC AAAC ABC kabel listrik tiga fase Kabel Bundel Udara ukuran
Pelabuhan: | Qingdao, Shanghai, Ningbo, Tianjin, Guangzhou, Dalian, Shenzhen, Yingkou |
Ketentuan Pembayaran: | L/C,D/P,T/T,Western Union,MoneyGram |
Kemampuan Pasokan: | 60000 Kilometer/kilometer per Month kapasitas ukuran tergantung pada kabel bundel udara |
Tempat asal: | Henan Cina |
Nama merek: | Hongda |
Nomor model: | Udara bundle kabel |
Bahan isolasi: | XLPE |
Jenis: | Tegangan Rendah |
Aplikasi: | Overhead |
Bahan konduktor: | Aluminium |
Jaket: | PVC |
Di atas lutut warna: | Hitam atau sebagai permintaan Anda |
Aplikasi: | Industri dan overhead |
Standar: | ASTM, BS NFC, IEC, DIN standar |
Properti: | Keamanan Tinggi & harga yang kompetitif |
Udara bundle kabel tegangan: | 0.6/1KV rendah voltgate |
Jumlah Core: | 12 3 4 5 6 core atau sesuai kebutuhan Anda |
Udara bundle kabel: | AWG10 16 25 35 50 70 95 120 150 |
Isolasi: | Isolasi PVC kabel kontrol |
Standar referensi: | NFC_33-209 |
Perincian Pengemasan: | ABC kabel (Kabel Bundel Udara) adalah mengadopsi untuk ekspor kayu drum, paket standar ekspor kayu besi drum atau lainnya. kami juga dapat pak sesuai dengan kebutuhan anda. |
ABC Kabel sampel: Kami dapat menawarkan sampel gratis. Jika memungkinkan kami juga dapat mendukung klip untuk fitting, pls merasa bebas untuk menghubungi saya.
0.6/1KV LV AAC AAAC ABC kabel listrik tiga fase overhead Bridge Bundel Kabel
Udara Bunched Kabel yang digunakan dalam pencurian daerah rawan, atau sebagai pengganti telanjang konduktor di daerah pedesaan, hutan berbukit medan. ini AB kabel memberikan sangat kinerja yang handal, perlindungan yang baik terhadap garis dan ground fault dan kemampuan beradaptasi yang baik. Dibuat dari bahan baku berkualitas, kabel ini tahan lama dan aman untuk listrik yang berbeda lingkungan. Fungsional ini kabel tersedia dalam dimensi standar dan juga dapat disesuaikan sesuai kebutuhan klien.
Fitur:
- HONGDA membuat Udara Bunched Kabel (ABC) adalah konsep baru untuk Overhead Sistem Distribusi Daya
- HONGDA membuat Udara Bunched Kabel yang dirancang, diproduksi dan diuji sesuai dengan ADALAH: 14255 ADALAH: 7098 (P-I) & internasional lainnya spesifikasi seperti IEC, NFC.
Aplikasi:
ABC dengan mudah dapat digunakan:
- Di pencurian daerah rawan
- Sebagai pengganti telanjang konduktor di daerah pedesaan, di hutan dan lain daerah seperti jalan-jalan sempit di mana ruang terbatas
- Sebagai pengganti telanjang melakukan di mana keandalan pasokan yang paling penting
- Sebagai pengganti telanjang garis di mana tingkat tinggi stabilitas tegangan adalah penting
- Di daerah perbukitan medan di mana perjalanan ereksi saluran udara atau di bawah tanah kabel menjadi sangat tinggi
- Sebagai penguatan sistem yang ada tanpa meningkatkan tegangan
- Untuk sementara perlengkapan
- Mengurangi pembakaran transformers dan perawatan
Keuntungan:
Dibandingkan dengan telanjang overhead jalur distribusi, AB Kabel memiliki kehandalan yang sangat tinggi selama layanan. Sebagai power dan netral konduktor terisolasi dengan yang terbaik bahan dielektrik, sehingga keuntungan sebagai berikut:
- Kurang tingkat kesalahan karena perlindungan yang baik terhadap garis dan ground fault Tinggi Angin atau jatuh pohon atau burung terutama di daerah perbukitan dan hutan yang dihadapi dalam Pedesaan Jaringan Distribusi
- Isolasi tinggi ketahanan terhadap bumi di semua tercemar suasana. Diabaikan arus dan kerugian rendah
- Beberapa sirkuit Listrik dan Kabel Telepon bisa digantung di set yang sama tiang atau lebih banyak seperti dinding dll
- Adaptasi lebih baik untuk menjalankan bersamaan dengan yang ada atas kepala bare conductor sistem tanpa gangguan
- Tinggi kapasitansi dan rendah induktansi terkemuka untuk impedansi rendah garis
- Lebih rendah tegangan, lebih tinggi saat ini membawa kapasitas vis-à-vis lebih baik Pengaturan Tegangan
- Lagi mencakup dan jarak yang lebih jauh garis mungkin dengan lebih baik stabilitas sistem
- AB Kabel jauh lebih aman kemudian telanjang Konduktor
- Bisa berakhir tergantung di vegetasi padat dan hutan
- Tambahan koneksi dapat dengan mudah dan cepat dibuat dengan hot-line konektor
- Total garis biaya dikurangi
- Biaya Pemeliharaan berkurang
- Sangat sulit untuk tekan AB kabel sehingga mengurangi pencurian yang menyebabkan lebih rendah distribusi kehilangan
Klik dan meminta Harga
ABC Kabel Aplikasi:
Dirakit insulated konduktor sesuai untuk digunakan dalam sistem memiliki standar tegangan operasi tidak melebihi 600 /1000 V. Inti dari udara dibundel konduktor akan diletakkan dengan kiri hand lay. Panjang lay akan 55-75 kali diameter konduktor fase.
ABC Kabel Konstruksi:
Konduktor akan terdampar melingkar dan, kecuali dinyatakan lain, harus sesuai dengan semua persyaratan untuk kelas 2 dipadatkan terdampar circular konduktor IEC60502.
1. Konduktor: Aluminium konduktor 2. isolasi: XLPE/PE
|
ABC Kabel Spesifikasi:
(1) mandiri
Phase |
Phase |
Phase |
|||
AAC + UV-XLPE |
Kompak Konduktor |
UV-XLPE Isolasi |
|||
Tidak X Normal Penampang Inti |
Jumlah Al Kabel |
Diameter keseluruhan |
Ketebalan Normal |
Minimum |
Diameter |
Tidak X mm2 |
– |
Mm |
Mm |
Mm |
Mm |
1X10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
1X16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
1X25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
1X35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
1X50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
1X70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
1X95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
1X120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
1X150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
1X185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
1X240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
2X10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
2X16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
2X25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
2X35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
2X50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
2X70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
2X95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
2X120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
2X150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
2X185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
2X240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
3X10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
3X16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
3X25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
3X35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
3X50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
3X70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
3X95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
3X120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
3X150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
3X185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
3X240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
4X10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
4X16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
4X25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
4X35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
4X50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
4X70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
4X95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
4X120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
4X150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
4X185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
4X240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
(2) Phase + Atau Netral Mengenai Saham
Phase | Atau netral mengenai saham | Phase | Atau netral mengenai saham | |||
AAC + UV-XLPE | AAAC | Kompak Konduktor | UV-XLPE Isolasi | Konduktor | ||
Tidak X Normal Cross Bagian Core |
Tidak X Normal Cross Bagian Core |
Jumlah Al Kawat | Keseluruhan Diameter |
Normal Ketebalan |
Minimum | Tidak/Diameter Al Alloy Wire |
Tidak X mm2 | Tidak X mm2 | – | Mm | Mm | Minimum | Tidak ada./mm |
1X16 | 1X16 | 7 | 4.8 | 1.2 | 0.98 | 7/1 70 |
1X25 | 1X25 | 7 | 6 | 1.2 | 0.98 | 7/2 10 |
1X35 | 1X35 | 7 | 7 | 1.4 | 1.16 | 7/2, 50 |
1X50 | 1X50 | 7 | 8.3 | 1.4 | 1.16 | 7/3. 00 |
1X70 | 1X70 | 19 | 9.8 | 1.4 | 1.16 | 7/3, 50 |
1X95 | 1X95 | 19 | 11.6 | 1.6 | 1.34 | 19/2, 50 |
1X120 | 1X120 | 19 | 13 | 1.6 | 1.34 | 19/2 80 |
1X150 | 1X150 | 19 | 14.6 | 1.8 | 1.52 | 37/2 25 |
1X185 | 1X185 | 36 | 16.2 | 2 | 1.7 | 37/2, 50 |
1X240 | 1X240 | 36 | 18.4 | 2.2 | 1.88 | 61/2 25 |
2X16 | 1X16 | 7 | 4.8 | 1.2 | 0.98 | 7/1 70 |
2X25 | 1X25 | 7 | 6 | 1.2 | 0.98 | 7/2 10 |
2X35 | 1X35 | 7 | 7 | 1.4 | 1.16 | 7/2, 50 |
2X50 | 1X50 | 7 | 8.3 | 1.4 | 1.16 | 7/3. 00 |
2X70 | 1X70 | 19 | 9.8 | 1.4 | 1.16 | 7/3, 50 |
2X95 | 1X95 | 19 | 11.6 | 1.6 | 1.34 | 19/2, 50 |
2X120 | 1X120 | 19 | 13 | 1.6 | 1.34 | 19/2 80 |
2X150 | 1X150 | 19 | 14.6 | 1.8 | 1.52 | 37/2 25 |
2X185 | 1X185 | 36 | 16.2 | 2 | 1.7 | 37/2, 50 |
2X240 | 1X240 | 36 | 18.4 | 2.2 | 1.88 | 61/2 25 |
3X16 | 1X16 | 7 | 4.8 | 1.2 | 0.98 | 7/1 70 |
3X25 | 1X25 | 7 | 6 | 1.2 | 0.98 | 7/2 10 |
3X35 | 1X35 | 7 | 7 | 1.4 | 1.16 | 7/2, 50 |
3X50 | 1X50 | 7 | 8.3 | 1.4 | 1.16 | 7/3. 00 |
3X70 | 1X70 | 19 | 9.8 | 1.4 | 1.16 | 7/3, 50 |
3X95 | 1X95 | 19 | 11.6 | 1.6 | 1.34 | 19/2, 50 |
3X120 | 1X120 | 19 | 13 | 1.6 | 1.34 | 19/2 80 |
3X150 | 1X150 | 19 | 14.6 | 1.8 | 1.52 | 37/2 25 |
3X185 | 1X185 | 36 | 16.2 | 2 | 1.7 | 37/2, 50 |
3X240 | 1X240 | 36 | 18.4 | 2.2 | 1.88 | 61/2 25 |
ABC Kabel sampel: Kami dapat menawarkan sampel gratis. Jika memungkinkan kami juga dapat mendukung klip untuk fitting, pls merasa bebas untuk menghubungi saya.
Kemasan & pengiriman
Detail kemasan: Kayu drum pack abc kabel kayu drum besi dan ekspor paket standar
Rincian pengiriman: 10-15 hari dan juga tergantung pada kuantitas
Drum ukuran:
Sesuai panjang kabel dan ukuran kontainer
* Untuk mengutip Anda akurat harga, silakan beritahu kami yang Anda butuhkan panjang kabel jumlah. Jumlah yang lebih besar, diskon lebih manfaat siap untuk Anda!
Pengiriman:
Port: Tianjin Qingdao atau Port Anda requireents.
Angkutan laut:
FOB/C & F/CIF membeli Semua tersedia.
Setiap memerlukan hubungi saya sebagai berikut:
Vivian Yuan | Direktur Penjualan
Zhengzhou Hongda Kabel, LTD.
Email: sale04 @ zzhongdacable.com.cn
ID Skype: xinyuanyy
Ponsel/WhatsApp/Wechat/ICQ: + 86 158 3829 0725
- Next: 0.6 1kV LV underwater waterproof power cable aluminum electrical cable
- Previous: 35 50 100 sq mm Aluminum Conductor Steel Reinforced overhead bare fox acsr dog rabbit conductor price list