<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>single insulated wire &#8211; JYTOP Cable</title>
	<atom:link href="https://indonesian.baoliyy.com/tag/single-insulated-wire/feed/" rel="self" type="application/rss+xml" />
	<link>https://indonesian.baoliyy.com</link>
	<description>Memproduksi KONDUKTOR AAC / AAAC / ACSR, Kabel XLPE, Kabel PVC, Kabel ABC, Kabel Listrik</description>
	<lastBuildDate>Sun, 15 Sep 2019 03:54:25 +0000</lastBuildDate>
	<language>id-ID</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.26</generator>
	<item>
		<title>Electrical wire single PVC insulated power cable thhn/thwn</title>
		<link>https://indonesian.baoliyy.com/electrical-wire-single-pvc-insulated-power-cable-thhn-thwn/</link>
				<comments>https://indonesian.baoliyy.com/electrical-wire-single-pvc-insulated-power-cable-thhn-thwn/#respond</comments>
				<pubDate>Sun, 15 Sep 2019 03:54:25 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[cncable]]></category>
		<category><![CDATA[cable thhn]]></category>
		<category><![CDATA[single insulated wire]]></category>
		<category><![CDATA[THHN\/THWN Electrical Wire]]></category>

		<guid isPermaLink="false">https://indonesian.baoliyy.com/electrical-wire-single-pvc-insulated-power-cable-thhn-thwn/</guid>
				<description><![CDATA[PVC insulated Kawat listrik/bangunan kawat/Wire Spesifikasi: &#160; 1. tegangan pengenal kabel harus sama atau lebih tinggi maka nilai tegangan sistem kabel digunakan pada sistem AC. Jika kabel digunakan di DC sistem tegangan pengenal sistem harus rendah maka 1.5 kali lebih tinggi nilai tegangan kabel dan kabel. Tegangan kerja dari sistem bisa menjadi 1.1 kali lebih [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="text-align: center"><span style="font-family: arial , helvetica , sans-serif;font-size: 24.0px"><strong>PVC insulated Kawat listrik/bangunan kawat/Wire</strong></span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Spesifikasi:</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 12.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">1. tegangan pengenal kabel harus sama atau lebih tinggi maka nilai tegangan sistem kabel digunakan pada sistem AC. Jika kabel digunakan di DC sistem tegangan pengenal sistem harus rendah maka 1.5 kali lebih tinggi nilai tegangan kabel dan kabel. Tegangan kerja dari sistem bisa menjadi 1.1 kali lebih tinggi tegangan pengenal kabel.</span><br /><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">2. Jangka panjang suhu kerja harus rendah maka 70<sup>O</sup>C. Suhu kerja BV-90 harus rendah maka 90<sup>O</sup>C Dan peletakan suhu harus lebih tinggi maka 0<sup>O</sup>C.</span><br /><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">3. kurva diameter kawat harus lebih dari 8 kali diameter diameter luar kabel dan kabel jika mereka diameter luar 25mm atau di atas. Jika diameter kabel dan kabel di atas 25mm, kurva diameter minimal 12 kali dari diameter luar kabel dan kabel.</span></p>
<p align="left">&nbsp;</p>
<div>
<div style="overflow:auto"><table style="width: 697.0px;height: 1424.0px" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="width: 147.0px">
<p align="center"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Tipe</span></p>
</td>
<td style="width: 160.0px">
<p align="center"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Nama</span></p>
</td>
<td style="width: 274.0px">
<p align="center"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Meletakkan tempat dan kebutuhan</span></p>
</td>
<td style="width: 103.0px">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Jangka panjang Suhu kerja<sup>0</sup>C</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">60227IEC01 05</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">BV</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">BLV</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor tembaga PVC kabel</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor aluminium PVC kabel</span></p>
</td>
<td style="width: 274.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Tetap diletakkan di dalam ruangan</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Conduit.</span></p>
</td>
<td style="width: 103.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">70</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">60227IEC07</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">(BV-90)</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Tahan panas konduktor tembaga PVC kawat terisolasi 90<sup>0</sup>C</span></p>
</td>
<td style="width: 274.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Terutama diletakkan di tempat lingkungan suhu tinggi dan dapat diletakkan di dalam ruangan, saluran.</span></p>
</td>
<td style="width: 103.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">90</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">BVR</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor tembaga PVC insulated kabel fleksibel</span></p>
</td>
<td style="width: 274.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Bisa untuk meletakkan tempat permanen di mana fleksibel.</span></p>
</td>
<td style="width: 103.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">70</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">60227IEC10</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">(BVV) BVV</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor tembaga PVC insulated PVC berselubung bulat kabel</span></p>
</td>
<td style="width: 274.0px" rowspan="4">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Tetap diletakkan, cocok untuk tempat dengan tinggi Perlindungan mekanik dan kelembaban, dapat diletakkan di udara atau di bawah tanah.</span></p>
</td>
<td style="width: 103.0px" rowspan="4">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">70</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">BLVV</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor aluminium PVC insulated PVC berselubung bulat kabel</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">BVVB</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor tembaga PVC insulated PVC berselubung datar kabel</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">BLVVB</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor aluminium PVC insulated PVC berselubung datar kabel</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">60227IEC02 (RV)</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">60227IEC06 (RV)</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor tembaga PVC insulated flexible connector wire</span></p>
</td>
<td style="width: 274.0px" rowspan="4">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Terutama digunakan di tengah dan terang gaya bergerak elektronik, peralatan rumah tangga, kekuatan dan pencahayaan dan tempat di mana fleksibel yang diperlukan</span></p>
</td>
<td style="width: 103.0px" rowspan="4">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">70</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">60227IEC42 (RVB)</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor tembaga berisolasi PVC datar fleksibel connector wire</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">RV</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor tembaga berisolasi PVC fleksibel memutar konektor kawat</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">60227IEC52 (RVV)</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">60227IEC53</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Konduktor tembaga PVC insulated PVC berselubung serba fleksibel connector wire</span></p>
</td>
</tr>
<tr>
<td style="width: 147.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">60227IEC08</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">(RV-90)</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
</td>
<td style="width: 160.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Cu konduktor tahan panas PVC insulated flexible connector wire 90<sup>0</sup>C</span></p>
</td>
<td style="width: 274.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">Terutama digunakan di tempat di mana tahan panas diperlukan</span></p>
</td>
<td style="width: 103.0px">
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">&nbsp;</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 18.0px">90</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px">Gambar menunjukkan:</span></p>
</div>
<div id="ali-anchor-AliPostDhMb-xzw79" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-xzw79" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Pabrik Menunjukkan</span></div>
<div style="padding: 10.0px 0">
<p style="text-align: left"><span style="font-size: 24.0px"><strong><span style="font-family: arial , helvetica , sans-serif">Proses produksi dari pabrik kami</span></strong></span></p>
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-2desa" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-2desa" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Produk lainnya</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 18.0px">Produk terkait:</span></p>
<p><span style="font-size: 18.0px">ABC Kabel: kabel Duplex, triplex kabel Quaint kabel</span></p>
<p><span style="font-size: 18.0px">Konsentris kabel: 1 core kabel 2 core kabel multi core</span></p>
<p><span style="font-size: 18.0px">Bare Conductor: AAC konduktor, AAAC Konduktor, ACSR konduktor</span></p>
<p><span style="font-size: 18.0px">Listrik kawat: kawat tembaga, kabel datar, thhn/thwn kabel</span></p>
<p>&nbsp;</p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-buu11" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-buu11" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Hubungi kami</span></div>
<div style="padding: 10.0px 0">
<p><strong><span style="font-size: 18.0px"><span style="font-family: arial , helvetica , sans-serif">Jangan ragu untuk menghubungi saya.</span></span></strong></p>
<div style="overflow:auto"><table style="border-collapse: collapse;width: 735.0px;height: 241.0px;border: 1.0px solid #cccccc" border="1" cellspacing="0">
<tbody>
<tr style="height: 32.3pt">
<td style="width: 134.0px;padding: 0.0pt 5.4pt;border: 1.0px solid #cccccc" rowspan="4" valign="top">
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</td>
<td style="width: 423.0px;padding: 0.0pt 5.4pt;border: 1.0px solid #cccccc;text-align: center;vertical-align: middle" valign="top">
<p style="text-align: left"><span style="font-size: 18.0px">E-mail: shcable010 (at) cnzzcable.com.cn</span></p>
<p style="text-align: left"><span style="font-size: 18.0px">(Dalam = @)</span></p>
</td>
</tr>
<tr style="height: 31.05pt">
<td style="width: 423.0px;padding: 0.0pt 5.4pt;border: 1.0px solid #cccccc;text-align: center;vertical-align: middle" valign="top">
<p style="text-align: left"><span style="font-size: 18.0px">TEL: + 86 15617579707</span></p>
</td>
</tr>
<tr style="height: 33.1pt">
<td style="width: 423.0px;padding: 0.0pt 5.4pt;border: 1.0px solid #cccccc;text-align: center;vertical-align: middle" valign="top">
<p style="text-align: left"><span style="font-size: 18.0px">Wechat/Whatsapp: 15617579707</span></p>
</td>
</tr>
<tr style="height: 33.1pt">
<td style="width: 423.0px;padding: 0.0pt 5.4pt;border: 1.0px solid #cccccc;text-align: center;vertical-align: middle" valign="top">
<p style="text-align: left"><span style="font-size: 18.0px">Nama: Echo Lu</span></p>
</td>
</tr>
</tbody>
</table></div>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://indonesian.baoliyy.com/electrical-wire-single-pvc-insulated-power-cable-thhn-thwn/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
