<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Power Cable 240mm &#8211; JYTOP Cable</title>
	<atom:link href="https://indonesian.baoliyy.com/tag/power-cable-240mm/feed/" rel="self" type="application/rss+xml" />
	<link>https://indonesian.baoliyy.com</link>
	<description>Memproduksi KONDUKTOR AAC / AAAC / ACSR, Kabel XLPE, Kabel PVC, Kabel ABC, Kabel Listrik</description>
	<lastBuildDate>Tue, 21 Jun 2022 01:02:00 +0000</lastBuildDate>
	<language>id-ID</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.30</generator>
	<item>
		<title>low voltage 0.6/1KV 4 core xlpe/pvc steel wire/steel tape armoured electric power cable 120mm 185mm 240mm</title>
		<link>https://indonesian.baoliyy.com/low-voltage-0-6-1kv-4-core-xlpe-pvc-steel-wire-steel-tape-armoured-electric-power-cable-120mm-185mm-240mm/</link>
				<comments>https://indonesian.baoliyy.com/low-voltage-0-6-1kv-4-core-xlpe-pvc-steel-wire-steel-tape-armoured-electric-power-cable-120mm-185mm-240mm/#respond</comments>
				<pubDate>Tue, 21 Jun 2022 01:02:00 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[vericable]]></category>
		<category><![CDATA[4 core armoured cable 120mm]]></category>
		<category><![CDATA[armoured electric power cable]]></category>
		<category><![CDATA[Power Cable 240mm]]></category>

		<guid isPermaLink="false">https://indonesian.baoliyy.com/?p=28219</guid>
				<description><![CDATA[Tegangan Rendah 0.6/1KV 4 core XLPE/PVC kawat baja/baja lapis baja pita kabel power listrik 120 MM 185mm 240mm &#160; Lihat informasi dasar untuk 1.1KV XLPE PVC listrik tegangan rendah kabel Aplikasi: Untuk power Networks, bawah tanah di luar ruangan dan di kabel ducting. Dianjurkan bahwa instalasi Petunjuk yang ditunjukkan oleh Listrik Lokal Kode atau setara, [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><span style="font-size: 18.0px;color: #ff0000;background-color: #ffff99">Tegangan Rendah 0.6/1KV 4 core XLPE/PVC kawat baja/baja lapis baja pita kabel power listrik 120 MM 185mm 240mm</span></p>
<p><span style="text-decoration: underline"><span style="color: #ff0000"><em><span style="font-size: 16.0px"></span></em></span></span></p>
<p>&nbsp;</p>
<p><strong><span style="font-size: 16.0px">Lihat informasi dasar untuk 1.1KV XLPE PVC listrik tegangan rendah kabel</span></strong></p>
<div style="overflow:auto"><table style="border-collapse: collapse;width: 686.0px;margin-left: 4.8pt;border: none;height: 823.0px" border="1" cellspacing="0">
<tbody>
<tr style="height: 16.35pt">
<td style="width: 120.0px;padding: 0.6pt;background: #ffffff;border: 1.0pt solid #cccccc" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Aplikasi:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: 1.0pt solid #cccccc;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Untuk power Networks, bawah tanah di luar ruangan dan di kabel ducting. Dianjurkan bahwa instalasi</span></p>
<p><span style="font-family: calibri;font-size: 16.0px">Petunjuk yang ditunjukkan oleh Listrik Lokal Kode atau setara, diikuti, sehingga menjaga</span></p>
<p><span style="font-family: calibri;font-size: 16.0px">Orang dan integritas produk tidak akan terpengaruh saat pemasangan.</span></p>
</td>
</tr>
<tr style="height: 16.35pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Referensi Standar:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">IEC60502-2 IEC 60228, IEC60332-1/2/3, BS5467, BS6724, GB/T 12706.</span></p>
</td>
</tr>
<tr style="height: 14.55pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Nilai Tegangan:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">0.6/1 KV</span></p>
</td>
</tr>
<tr style="height: 19.55pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Nomor inti:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Single Core (1C); Dua core (2C) Tiga Inti (3C); empat Core (4C) Lima Inti (5C)</span></p>
</td>
</tr>
<tr style="height: 29.35pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Dimensi yang tersedia:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">1.5mm2, 2.5mm2; 4mm2; 6mm2; 10MM2; 16mm2; 25mm2, 35mm2, 50mm2, 70mm2, 95mm2,</span><span style="font-family: calibri;font-size: 16.0px">120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2.</span></p>
</td>
</tr>
<tr style="height: 31.75pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-size: 16.0px">Kode</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-size: 14.0px"><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">NYY/VV</span><span style="color: #000000;font-style: normal;background: #ffffff">;</span><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">N2XY/YJV</span><span style="color: #000000;font-style: normal;background: #ffffff">;</span><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">VV72</span><span style="color: #000000;font-style: normal;background: #ffffff">;</span><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">YJV72</span><span style="color: #000000;font-style: normal;background: #ffffff">;</span><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">NYBY/VV22</span><span style="color: #000000;font-style: normal;background: #ffffff">;</span><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">N2XBY/YJV22</span><span style="color: #000000;font-style: normal;background: #ffffff">;</span><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">NYRY/VV32</span><span style="color: #000000;font-style: normal;background: #ffffff">;</span><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">NAYRY/VLV32</span><span style="color: #000000;font-style: normal;background: #ffffff">;</span><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">N2XRY/YJV32</span><span style="color: #000000;font-style: normal;background: #ffffff">;</span><span style="font-family: arial;color: #000000;font-style: normal;background: #ffffff">NA2XRY/YJLV32</span></span></p>
</td>
</tr>
<tr style="height: 14.65pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Konstruksi:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">0.6/1kV CU atau AL/PVC/SWA atau STA/PVC</span></p>
</td>
</tr>
<tr style="height: 15.0pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Konduktor:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Terdampar bulat padat konduktor tembaga (Cu), kawat tembaga anil.</span></p>
</td>
</tr>
<tr style="height: 13.45pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Isolasi:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">PVC atau XLPE</span></p>
</td>
</tr>
<tr style="height: 12.5pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Pengisi:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Tali PP</span></p>
</td>
</tr>
<tr style="height: 12.95pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Pemisah:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Mengikat pita</span></p>
</td>
</tr>
<tr style="height: 12.15pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Seprai:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">PVC (Polyvinyl Chloride)</span></p>
</td>
</tr>
<tr style="height: 16.3pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Armored:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Kawat Baja galvanis Armour (SWA/GSWA), kawat Aluminium Armour (AWA)</span></p>
</td>
</tr>
<tr style="height: 11.8pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Selubung:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">PVC (Polyvinyl Chloride), tahan api PVC, PE LSOH, HFFR</span></p>
</td>
</tr>
<tr style="height: 11.1pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Warna:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Merah atau Hitam</span></p>
</td>
</tr>
<tr style="height: 15.4pt">
<td style="width: 120.0px;padding: 0.6pt;border-left: 1.0pt solid #cccccc;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-family: calibri;font-size: 16.0px">Peringkat suhu:</span></p>
</td>
<td style="width: 560.0px;padding: 0.6pt;border-left: none;border-right: 1.0pt solid #cccccc;border-top: none;border-bottom: 1.0pt solid #cccccc;background: #ffffff" valign="center">
<p><span style="font-size: 16.0px"><span style="font-family: calibri">0 &deg;C untuk<span style="font-size: 14.0px">7</span></span><span style="font-size: 14.0px">0<span style="font-family: calibri">&deg;C</span>Untuk kabel PVC</span></span></p>
<p><span style="font-size: 14.0px"><span style="font-family: calibri">0 &deg;C untuk</span>90<span style="font-family: calibri">&deg;C</span>Untuk kabel XLPE</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="margin: 0.0px;padding: 0.0px;font-style: normal;font-weight: normal;font-size: 12.0px;line-height: inherit;font-family: arial , helvetica;border-collapse: collapse;width: 696.0px;background: #ffffff;color: #333333;height: 393.0px" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 20.25pt" align="left">
<td>
<p><span style="font-size: 14.0px">Kode</span></p>
</td>
<td><span style="font-size: 14.0px">Konstruksi</span></td>
<td><span style="font-size: 14.0px">Tegangan Rendah Kabel XLPE Deskripsi</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 14.25pt" align="left">
<td><span style="font-size: 14.0px">NYY/VV</span></td>
<td><span style="font-size: 14.0px">CU/PVC/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor tembaga isolasi PVC selubung PVC kabel listrik</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 14.25pt" align="left">
<td><span style="font-size: 14.0px">N2XY/YJV</span></td>
<td><span style="font-size: 14.0px">CU/XLPE/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor tembaga XLPE isolasi PVC selubung kabel listrik</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 14.25pt" align="left">
<td><span style="font-size: 14.0px">VV72</span></td>
<td><span style="font-size: 14.0px">CU/PVC/AWA/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor tembaga isolasi PVC aluminium wire armoring selubung PVC kabel listrik</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 14.25pt" align="left">
<td><span style="font-size: 14.0px">YJV72</span></td>
<td><span style="font-size: 14.0px">CU/XLPE/AWA/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor tembaga XLPE isolasi aluminium wire armoring selubung PVC kabel listrik</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 22.5pt" align="left">
<td><span style="font-size: 14.0px">NYBY/VV22</span></td>
<td><span style="font-size: 14.0px">CU/PVC/PVC/STA/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor tembaga PVC isolasi PVC selubung batin pita baja armoring selubung PVC kabel listrik</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 22.5pt" align="left">
<td><span style="font-size: 14.0px">N2XBY/YJV22</span></td>
<td><span style="font-size: 14.0px">CU/XLPE/PVC/STA/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor tembaga XLPE isolasi PVC selubung batin pita baja armoring selubung PVC kabel listrik</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 22.5pt" align="left">
<td><span style="font-size: 14.0px">NYRY/VV32</span></td>
<td><span style="font-size: 14.0px">CU/PVC/PVC/SWA/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor tembaga PVC isolasi PVC selubung batin kawat baja armoring selubung PVC kabel listrik</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 22.5pt" align="left">
<td><span style="font-size: 14.0px">NAYRY/VLV32</span></td>
<td><span style="font-size: 14.0px">AL/PVC/PVC/SWA/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor aluminium PVC isolasi PVC selubung batin kawat baja armoring selubung PVC kabel listrik</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 22.5pt" align="left">
<td><span style="font-size: 14.0px">N2XRY/YJV32</span></td>
<td><span style="font-size: 14.0px">CU/XLPE/PVC/SWA/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor tembaga XLPE isolasi PVC selubung batin kawat baja armoring selubung PVC kabel listrik</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-style: inherit;font-weight: inherit;font-size: 12.0px;line-height: inherit;height: 22.5pt" align="left">
<td><span style="font-size: 14.0px">NA2XRY/YJLV32</span></td>
<td><span style="font-size: 14.0px">AL/XLPE/PVC/SWA/PVC</span></td>
<td><span style="font-size: 14.0px">Konduktor aluminium XLPE isolasi PVC selubung batin kawat baja armoring selubung PVC kabel listrik</span></td>
</tr>
</tbody>
</table></div>
<p>&nbsp;<strong><span style="font-size: 16.0px">Gambar terperinci:</span></strong></p>
<div id="ali-anchor-AliPostDhMb-mutki" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-mutki" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Gambar rinci LV</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<p><span style="font-size: 16.0px"><strong>Spesifikasi LV isolasi PVC SWA 4 core lapis baja listrik tegangan rendah kabel</strong></span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-6oke7" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-6oke7" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Spesifikasi LV</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-ng2mo" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-ng2mo" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Ikhtisar produk</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="text-decoration: underline"><strong><span style="font-size: 16.0px">ZMS rincian Kemasan</span></strong></span></p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-qxc88" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-qxc88" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<h1>FAQ</h1>
<ul>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Apakah Anda sebuah pabrik atau perusahaan perdagangan?</dt>
<dd>A: Kami adalah pabrik dengan kami perusahaan perdagangan. Kami bisnis perdagangan memperluas dan luar negeri.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Kapan SAYA bisa mendapatkan Harga?</dt>
<dd>A: Kami biasanya mengutip dalam waktu 12 jam setelah kami mendapatkan pertanyaan Anda. Jika Anda sangat mendesak untuk mendapatkan harga, silahkan hubungi kami atau memberitahu kami di email Anda sehingga Kami akan menganggap prioritas pertanyaan Anda.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Bagaimana SAYA bisa mendapatkan sampel untuk memeriksa kualitas Anda?</dt>
<dd>A: Setelah konfirmasi harga, Anda dapat meminta untuk sampel untuk memeriksa kualitas kami. Sampel gratis, tapi biaya pengiriman harus dibayar.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Apa Kuantitas Minimum Order?</dt>
<dd>A: Umumnya, 1000 meters untuk bangunan kawat. Untuk kabel listrik, lapis baja atau unarmored 500 meters.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Yang standar untuk produk Anda?</dt>
<dd>A: Kami dapat memproduksi kawat dan kabel sesuai dengan standar internasional: IEC, ASTM, BS DIN, SANS, CSA atau sebagai kebutuhan pelanggan.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Bagaimana dengan waktu Pengiriman?</dt>
<dd>A: Jika kita memiliki saham, pengiriman akan sangat cepat. Untuk yang baru diproduksi produk 15 sampai 25 hari untuk produksi.</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: ketentuan Pembayaran:</dt>
<dd>A: Biasanya 30% dibayar sebagai pembayaran di muka, keseimbangan dibayar sebelum Pengiriman. Atau 100% L/C pada pandangan</dd>
</dl>
</li>
<li style="border-bottom: 1.0px solid #eeeeee">
<dl>
<dt>Q: Apa kemasan Anda?</dt>
<dd>A: Kami kabel listrik menggunakan kabel listrik roda untuk packing roda dapat baja, rangka baja dan difumigasi kayu atau kayu difumigasi kasus. Kami menggunakan kemasan yang berbeda untuk berbagai panjang kabel, untuk memastikan tidak akan ada masalah selama pengiriman produk.</dd>
</dl>
</li>
</ul>
</div>
</div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://indonesian.baoliyy.com/low-voltage-0-6-1kv-4-core-xlpe-pvc-steel-wire-steel-tape-armoured-electric-power-cable-120mm-185mm-240mm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>Low voltage 0.6/1kV copper conductor PVC/XLPE insulated power cable 240mm</title>
		<link>https://indonesian.baoliyy.com/low-voltage-0-6-1kv-copper-conductor-pvc-xlpe-insulated-power-cable-240mm/</link>
				<comments>https://indonesian.baoliyy.com/low-voltage-0-6-1kv-copper-conductor-pvc-xlpe-insulated-power-cable-240mm/#respond</comments>
				<pubDate>Tue, 21 Jun 2022 00:08:04 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[sonorouscable]]></category>
		<category><![CDATA[240mm power cable]]></category>
		<category><![CDATA[cable 240mm]]></category>
		<category><![CDATA[Power Cable 240mm]]></category>

		<guid isPermaLink="false">https://indonesian.baoliyy.com/low-voltage-0-6-1kv-copper-conductor-pvc-xlpe-insulated-power-cable-240mm/</guid>
				<description><![CDATA[0.6/1kv Cu/PVC/XLPE insulated kabel listrik 240mm &#160; &#160; jenis utama: 1. PVC/XLPE insulated Kabel Listrik 0.6/1 kV (tanpa armour) ini berlaku untuk jalur transmisi dan distribusi daya listrik dengan AC tegangan U0/U sampai dengan 0.6/1 kV. untuk instalasi outdoor dan indoor di basah dan tempat basah, diletakkan langsung di tanah (bila baik melindungi di saluran, [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p align="left" style="background: white;text-align: center"><span style="color: #0000ff;font-family: times new roman , times;font-size: 24.0px;background-color: #ffffff"><strong>0.6/1kv Cu/PVC/XLPE insulated kabel listrik 240mm</strong></span></p>
<p align="left" style="background: white;text-align: center">&nbsp;</p>
<p align="left" style="background: white;text-align: center">&nbsp;</p>
<p><span style="text-decoration: underline"><span style="color: #0000ff;font-size: 16.0px"><strong><span style="font-family: times new roman , times">jenis utama:</span></strong></span></span></p>
<p><strong><span style="font-family: times new roman , times;font-size: 16.0px">1. PVC/XLPE insulated Kabel Listrik 0.6/1 kV (tanpa armour)</span></strong></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">ini berlaku untuk jalur transmisi dan distribusi daya listrik dengan AC tegangan U<sub>0</sub>/U sampai dengan 0.6/1 kV. untuk instalasi outdoor dan indoor di basah dan tempat basah, diletakkan langsung di tanah (bila baik melindungi di saluran, di parit dan dalam baja kurung dukungan.)</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 16.0px"></span></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 16.0px">2. PVCXLPE terisolasi Kabel Power 0.6/1 kV dengan pita baja armourd (STA)</span></strong></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">ini berlaku untuk jalur transmisi dan distribusi daya listrik dengan AC tegangan U<sub>0</sub>/U sampai dengan 0.6/1 kV. untuk instalasi outdoor dan indoor di basah dan tempat basah, tekanan diletakkan langsung di tanah di mana berlebihan mekanik yang hadir dalam medan dan dalam peletakan vertikal atau miring miring dan bergerak, serta di lokasi rentan terhadap geser.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: times new roman , times;font-size: 16.0px">3. PVC/<span style="font-family: times new roman , times"><span style="font-size: 16.0px">XLPE terisolasi Kabel Power 0.6/1 kV dengan kawat baja armourd (SWA)</span></span></span></strong></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">ini berlaku untuk jalur transmisi dan distribusi daya listrik dengan AC tegangan U<sub>0</sub>/U sampai dengan 0.6/1 kV. untuk meletakkan di dalam ruangan, dalam terowongan, kabel parit, dengan baik atau langsung di tanah, mampu menanggung kekuatan mekanik eksternal, dan kekuatan tertentu</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"><span style="font-family: times new roman , times"><span style="font-size: 16.0px"></span></span></span></p>
<p style="text-align: left">&nbsp;</p>
<p style="text-align: left">&nbsp;</p>
<div style="overflow:auto"><table style="width: 662.0px;height: 468.0px" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 22.7pt" align="left">
<td style="width: 191.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">tegangan</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">0.6/1 kV</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td style="width: 191.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">core</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">1C, 2C, 3C, 4C, 5C, 3C + 1E, 4C + 1E, 3C + 2E</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td style="width: 191.4pt" align="right">
<p align="right" style="text-align: left"><span style="font-family: times new roman , times;font-size: 16.0px">kisaran Nominal penampang</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">1.5-630 mm2</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td style="width: 191.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">standar</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">IEC 60502, BS 7870, GB/T12706</span></p>
</td>
</tr>
<tr style="height: 18.9pt" align="left">
<td style="width: 191.4pt;height: 18.9pt" rowspan="4">
<p><span style="font-family: times new roman , times;font-size: 16.0px">konstruksi</span></p>
</td>
<td style="width: 70.85pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">konduktor:</span></p>
</td>
<td style="width: 276.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">kelas 1/2 anil telanjang tembaga padat atau untai</span></p>
</td>
</tr>
<tr style="height: 18.75pt" align="left">
<td style="width: 70.85pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">isolasi:</span></p>
</td>
<td style="width: 276.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">XLPE</span></p>
</td>
</tr>
<tr style="height: 34.0pt" align="left">
<td style="width: 70.85pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">armor:</span></p>
</td>
<td style="width: 276.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">SWA (Catatan: untuk single core baju besi harus AWA atau SSWA)</span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">STA (Catatan: untuk single core baju besi harus ATA atau SSTA)</span></p>
</td>
</tr>
<tr style="height: 18.75pt" align="left">
<td style="width: 70.85pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">selubung:</span></p>
</td>
<td style="width: 276.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">PVC, PE atau LSZH</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td style="width: 191.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">Max. Suhu Operasi</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">PVC: 90 &amp; #8451;, dapat 90 &amp; #8451; dan 110 &amp; #8451; sesuai kebutuhan</span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">XLPE:<span style="font-family: times new roman;font-size: medium">90 &amp; #8451;, dapat 105 &amp; #8451; dan 110 &amp; #8451; sesuai kebutuhan</span> </span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td style="width: 191.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">Packing</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">kayu drum atau sesuai kebutuhan</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td style="width: 191.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">Kapasitas produksi</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">30 kilometer/hari</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td style="width: 191.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">MOQ</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">1000 meters untuk ukuran kecil, 500 meters untuk ukuran besar.</span></p>
</td>
</tr>
<tr style="height: 22.7pt" align="left">
<td style="width: 191.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">waktu pengiriman</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">10-15 hari kerja</span></p>
</td>
</tr>
<tr style="height: 45.35pt" align="left">
<td style="width: 191.4pt">
<p><span style="font-family: times new roman , times;font-size: 16.0px">komentar</span></p>
</td>
<td style="width: 347.25pt" colspan="2">
<p><span style="font-family: times new roman , times;font-size: 16.0px">kabel dapat dari menghambat api, tahan api, ramah lingkungan atau properti lainnya</span></p>
</td>
</tr>
</tbody>
</table></div>
<p align="left" style="background: white"><span style="font-family: times new roman , times;font-size: 16.0px"><span style="color: #333333"></span></span></p>
<p align="left" style="background: white"><span style="font-family: times new roman , times;font-size: 16.0px"><span style="color: #333333"></span></span></p>
<p align="left" style="background: white"><span style="color: #0000ff;text-decoration: underline"><strong><span style="font-family: times new roman , times;font-size: 16.0px">struktur:</span></strong></span></p>
<p align="left" style="background: white">&nbsp;</p>
<p align="left" style="background: white">&nbsp;</p>
<p align="left" style="background: white">&nbsp;</p>
<p align="left" style="background: white">&nbsp;</p>
<p align="left" style="background: white">&nbsp;</p>
<p>&nbsp;</p>
<p><span style="text-decoration: underline"><span style="color: #0000ff;line-height: normal;font-family: times new roman , times;font-size: 16.0px;font-style: normal;font-weight: normal;text-decoration: underline"><strong>aplikasi:</strong></span></span></p>
<p><span style="text-decoration: underline"><span style="color: #0000ff;line-height: normal;font-family: times new roman , times;font-size: 16.0px;font-style: normal;font-weight: normal;text-decoration: underline"><strong></strong></span></span></p>
<p>&nbsp;</p>
<p><span style="text-decoration: underline"><span style="color: #0000ff;line-height: normal;font-family: times new roman , times;font-size: 16.0px;font-style: normal;font-weight: normal;text-decoration: underline"><strong></strong></span></span></p>
<p align="left" style="background: white">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Hongliang Kabel Co, ltd (Markas)</span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">didirikan Tahun: 2004</span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">modal terdaftar dari RMB: 201,800,000</span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Total aset: 28.7 juta</span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Area pabrik: 45425 mm2</span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">Kapasitas produksi per tahun: 250000 km</span></p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">jumlah Karyawan: 460</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-family: times new roman , times;font-size: 16.0px"><span style="color: #0000ff;text-decoration: underline"><span style="background-color: #ffffff"><strong>produk utama:</strong></span></span>kabel Power, kawat kabel listrik, di bawah tegangan 35kV PVC/XLPE terisolasi kabel, lapis baja kabel, kontrol kabel, karet kabel, PVC terisolasi kawat dan kabel, BV kawat, kawat rumah,<span style="font-family: times new roman;font-size: medium">telanjang terdampar konduktor (AAC, ACSR, AAAC, ACAR);</span>khusus Kabel dll</span></p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-sk89l" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-sk89l" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p><span style="color: #0000ff;font-family: times new roman , times;font-size: 16.0px"><strong>1.</strong></span><span style="color: #0000ff;font-family: times new roman , times;font-size: 16.0px;text-decoration: underline"><strong>yang syarat pembayaran yang anda terima?</strong></span></p>
</div>
</div>
<p><span style="font-family: times new roman , times;font-size: 16.0px">a) 30% DEPOSIT DI ADVINCE, BANLANCE TERHADAP SALINAN B/L.</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">b) 100% L/C pada pandangan.</span></p>
<p><span style="color: #0000ff;font-family: times new roman , times;font-size: 16.0px"><strong>2.</strong></span><span style="color: #0000ff;font-family: times new roman , times;font-size: 16.0px;text-decoration: underline"><strong>apa MOQ anda?</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">anda disarankan untuk silahkan konfirmasi dengan kami langsung sebagai berdasarkan kabel yang berbeda. biasanya itu 100 meters</span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">untuk kabel tegangan menengah.</span></p>
<p><span style="color: #0000ff;font-family: times new roman , times;font-size: 16.0px"><strong>3.</strong></span><span style="color: #0000ff;font-family: times new roman , times;font-size: 16.0px;text-decoration: underline"><strong>bagaimana dengan waktu pengiriman?</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">sesuai dengan jumlah pesanan. biasanya adalah 15 30 hari kerja.</span></p>
<p><span style="color: #0000ff;font-family: times new roman , times;font-size: 16.0px"><strong>4.</strong></span><span style="color: #0000ff;font-family: times new roman , times;font-size: 16.0px;text-decoration: underline"><strong>cara kemasan barang?</strong></span></p>
<p><span style="font-family: times new roman , times;font-size: 16.0px">biasanya dalam drum kayu atau baja drum kayu. kabel kawat biasanya melingkar.</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="color: black;font-family: times new roman , serif;font-size: 12.0pt"></span></p>
<p align="left">&nbsp;</p>
<p align="left"><span style="color: #0000ff"><span style="font-size: 16.0px"><strong>Ponsel:</strong>0086-15106980528<strong>S</strong></span><span style="font-size: 16.0px"><strong>kype:</strong>hongliangcablesales7</span></span></p>
<p align="left">
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://indonesian.baoliyy.com/low-voltage-0-6-1kv-copper-conductor-pvc-xlpe-insulated-power-cable-240mm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>600 1000V AL or CU Conductor XLPE Insulated Power Cable 240mm</title>
		<link>https://indonesian.baoliyy.com/600-1000v-al-or-cu-conductor-xlpe-insulated-power-cable-240mm/</link>
				<comments>https://indonesian.baoliyy.com/600-1000v-al-or-cu-conductor-xlpe-insulated-power-cable-240mm/#respond</comments>
				<pubDate>Thu, 19 Mar 2020 11:14:58 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[240 sq mm]]></category>
		<category><![CDATA[600 1000V AL or CU Conductor]]></category>
		<category><![CDATA[Power Cable 240mm]]></category>

		<guid isPermaLink="false">https://indonesian.baoliyy.com/600-1000v-al-or-cu-conductor-xlpe-insulated-power-cable-240mm/</guid>
				<description><![CDATA[600 1000 V AL atau CU Konduktor XLPE Insulated Kabel Listrik 240mm &#160; Aplikasi Digunakan untuk transmisi listrik dan jalur distribusi dengan tegangan peringkat 35kV dan di bawah ini. dibandingkan dengan PVC Insulated Kabel Listrik, xlpe kabel listrik menawarkan tidak hanya karakteristik yang sangat baik listrik mekanisme panas dan penuaan tahan lingkungan tahan stres dan [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><span style="font-size: 14.0px"><strong>600 1000 V AL atau CU Konduktor XLPE Insulated Kabel Listrik 240mm</strong></span></p>
<p align="left">
<p align="left">&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Aplikasi</span></strong></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Digunakan untuk transmisi listrik dan jalur distribusi dengan tegangan peringkat 35kV dan di bawah ini. dibandingkan dengan PVC Insulated Kabel Listrik, xlpe kabel listrik menawarkan tidak hanya karakteristik yang sangat baik listrik mekanisme panas dan penuaan tahan lingkungan tahan stres dan tahan korosi kimia, tapi juga struktur sederhana, ringan, tidak ada pembatasan dengan meletakkan drop, Dan suhu tinggi allowance untuk jangka panjang.</span></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Standar</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Internasional: IEC 60502-2, IEC 60228</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">China</span><span style="font-family: arial;color: #231f20;font-size: 10.0pt">: GB/T 12706.2-2008</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Standar lainnya seperti</span><span style="font-family: arial;color: #333333;font-size: 10.0pt">BS, DIN dan ICEA atas permintaan</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Data teknis</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Tegangan: 0.6/1kV 1.8/3kV, 6/10kV 8.7/10kV, 8.7/15kV 12/20kV, 21/35kV 26/35kV</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Maksimum Konduktor Suhu: Di bawah normal (90<span style="color: #333333">&deg;C</span>), Darurat (130<span style="color: #333333">&deg;C</span>) Atau hubungan pendek tidak lebih dari 5 s (250<span style="color: #333333">&deg;C</span>) Kondisi.</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Min Suhu Ambien.</span><span style="font-family: arial;color: #333333;font-size: 10.0pt">0 &deg;C, setelah instalasi dan hanya jika kabel dalam posisi tetap</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">Minimum Bending Radius: 20 x Kabel OD untuk single-core non-lapis baja kabel</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x Kabel OD untuk single-core lapis baja kabel</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x Kabel OD untuk multi core non-lapis baja kabel</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">12 x Kabel OD untuk multi-core lapis baja kabel</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">Sertifikat</span></strong></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">CE, RoHS, CCC, KEMA dan lain-lain sesuai permintaan</span></p>
<p align="left">&nbsp;</p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">Rincian lainnya:</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt"><br />Spesifikasi</span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 33.0pt" align="left">
<td style="width: 36.8pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV</span></p>
</td>
<td style="width: 175.2pt;background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Konduktor tembaga, XLPE Insulated, PVC Berselubung Kabel Listrik</span></p>
</td>
<td style="width: 220.3pt;background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Untuk meletakkan di dalam ruangan dan di luar ruangan. Mampu menanggung tertentu traksi saat pemasangan, tapi tidak mekanis eksternal pasukan. Meletakkan single core di magnetic saluran tidak diperbolehkan.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Konduktor, XLPE Insulated, PVC Berselubung Kabel Listrik</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Konduktor tembaga, XLPE Insulated PE Dilapisi Kabel Listrik</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Untuk meletakkan di dalam ruangan dan di luar ruangan. Mampu menanggung tertentu traksi saat pemasangan, tapi tidak mekanis eksternal pasukan. Meletakkan single core di magnetic saluran tidak diperbolehkan.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLY</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Konduktor, XLPE Insulated PE Dilapisi Kabel Listrik</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">XLPE Insulated, Pita Baja Lapis Baja, PVC Berselubung Kabel Listrik</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Cocok untuk mengubur di tanah Dapat bear mekanik eksternal pasukan tapi besar menarik pasukan.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Terisolasi, Pita Baja Lapis Baja, PVC Berselubung Kabel Listrik</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Konduktor tembaga, XLPE Insulated Halus Kawat Baja Lapis Baja, PVC Berselubung Kabel Listrik</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Berlaku untuk poros, air dan tanah, mampu menanggung lebih besar tekanan positif.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al Konduktor, XLPE Insulated Halus Kawat Baja Lapis Baja, PVC Berselubung Kabel Listrik</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Konduktor tembaga, XLPE Insulated Tebal Kawat Baja Lapis Baja, PVC Berselubung Kabel Listrik</span></p>
</td>
<td style="height: 33.0pt" rowspan="2">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Untuk meletakkan poros air bawah tanah dan besar diference tingkat, mampu menanggung eksternal tekanan mekanis dan sedang menarik kekuatan.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al Konduktor, XLPE Insulated Tebal Kawat Baja Lapis Baja, PVC Berselubung Kabel Listrik</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-family: arial;font-size: 10.0pt">&nbsp;</span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://indonesian.baoliyy.com/600-1000v-al-or-cu-conductor-xlpe-insulated-power-cable-240mm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
