<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>PE\/XLPE Insulated PVC Sheath NYCY Concentric Cabl &#8211; JYTOP Cable</title>
	<atom:link href="https://indonesian.baoliyy.com/tag/pe-xlpe-insulated-pvc-sheath-nycy-concentric-cabl/feed/" rel="self" type="application/rss+xml" />
	<link>https://indonesian.baoliyy.com</link>
	<description>Memproduksi KONDUKTOR AAC / AAAC / ACSR, Kabel XLPE, Kabel PVC, Kabel ABC, Kabel Listrik</description>
	<lastBuildDate>Thu, 12 Sep 2019 04:40:14 +0000</lastBuildDate>
	<language>id-ID</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.28</generator>
	<item>
		<title>PE/XLPE Insulated PVC Sheath NYCY Concentric Cable</title>
		<link>https://indonesian.baoliyy.com/pe-xlpe-insulated-pvc-sheath-nycy-concentric-cable/</link>
				<comments>https://indonesian.baoliyy.com/pe-xlpe-insulated-pvc-sheath-nycy-concentric-cable/#respond</comments>
				<pubDate>Thu, 12 Sep 2019 04:40:14 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[CABLE]]></category>
		<category><![CDATA[Concentric Cable]]></category>
		<category><![CDATA[PE\/XLPE Insulated PVC Sheath NYCY Concentric Cabl]]></category>

		<guid isPermaLink="false">https://indonesian.baoliyy.com/pe-xlpe-insulated-pvc-sheath-nycy-concentric-cable/</guid>
				<description><![CDATA[Specifications 600 Volt Copper/Aluminum Concentric Cable ISO Standard IEC/ASTM/BS and so on Aluminum Conductor Copper Concentric Cable &#160; Standard:&#160;&#160;LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h3>Specifications</h3>
<p>600 Volt Copper/Aluminum Concentric Cable <br />ISO Standard <br />IEC/ASTM/BS and so on</p>
<p><span style="color: #800000"><strong><span style="font-size: 12.0pt">Aluminum Conductor Copper Concentric Cable </span></strong></span></p>
<div id="J-rich-text-description">
<p><strong><span style="font-size: 12.0pt">&nbsp;</span></strong></p>
<p><strong>Standard:</strong>&nbsp;&nbsp;LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors</p>
<p>&nbsp;</p>
<div style="text-align: left;padding-bottom: 10.0px">
<p><strong>Conductors:</strong> Stranded Annealed Copper</p>
<p><strong>Insulation:</strong> XLPE/PE/PVC(Cross-linked Polyethylene)<br /><strong>Concentric layer:</strong> Single layer of plain annealed copper wires</p>
<p><strong>Sheath/Jacket:</strong> XLPE /PVC(Cross-linked Polyethylene)</p>
<p>&nbsp;</p>
<p><strong>Voltage:</strong> 600/1000v&nbsp;&nbsp;</p>
<p><strong>Operating temperature:</strong> Maximum 90&deg;C, minimum&nbsp;-30&deg;C</p>
<p>&nbsp;</p>
<p><strong>Common Used Colours:</strong></p>
<p>For insulation: White, Black and Red.</p>
<p>For external jacket: Black</p>
<p>&nbsp;</p>
<p><strong>PACKAGING:</strong></p>
<p>Wooden Drum</p>
<p>Or length to the client&#039;s requirement.</p>
<p>&nbsp;</p>
<p><strong>Available Size: MM2, AWG or MCM</strong></p>
<p>10 16 25 35 50 70 95</p>
<p>2 x 8 2 x 6 2 x 4 2 x 2 2 x 1/0 2 x 2/0 2&#215;8 2&#215;10</p>
<p>3 x 8 2&#215;6 3 x 6 2&#215;4 3 x 4 2&#215;2 3 x 2</p>
<p>3 x 1 0 3 x 2/0 4 x 8 4 x 6 4 x 4 4 x 2</p>
<p>250 300 and so on</p>
<p>&nbsp;</p>
<p><strong>Application</strong></p>
<p>Power cables for energy supply are used for industry and distribution boards, power stations, house connecting boxes and street lighting as well as control cable for the transmission of control impulses and test data. Overall, where increased electrical and also mechanical protection are required. Those cables are installed in open air, in underground, in water, indoors and in cable ducts. The concentric conductor (C) is allowed to use as PE-, PEN-conductor or as shield. due to the typical construction of concentric conductors it is possible to obtain many more cable joints, without cutting any conductor. In that way the operating reliability is guaranteed.</p>
</div>
</div>
<h3></h3>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://indonesian.baoliyy.com/pe-xlpe-insulated-pvc-sheath-nycy-concentric-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>