<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ICE Certification XLPE Fire Resistant Cable With 25 Years Manufacturer &#8211; JYTOP Cable</title>
	<atom:link href="https://indonesian.baoliyy.com/tag/ice-certification-xlpe-fire-resistant-cable-with-25-years-manufacturer/feed/" rel="self" type="application/rss+xml" />
	<link>https://indonesian.baoliyy.com</link>
	<description>Memproduksi KONDUKTOR AAC / AAAC / ACSR, Kabel XLPE, Kabel PVC, Kabel ABC, Kabel Listrik</description>
	<lastBuildDate>Thu, 19 Mar 2020 11:30:04 +0000</lastBuildDate>
	<language>id-ID</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.28</generator>
	<item>
		<title>Fire retardant cable fire resistant FRC power cable</title>
		<link>https://indonesian.baoliyy.com/fire-retardant-cable-fire-resistant-frc-power-cable/</link>
				<comments>https://indonesian.baoliyy.com/fire-retardant-cable-fire-resistant-frc-power-cable/#respond</comments>
				<pubDate>Thu, 19 Mar 2020 11:30:04 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[Fire Rated Cable mica fire resistant cable Can Pass IEC60331 BS6387C.W.Z AS\/NZS3013 WS52FIRE TEST Good quality and better Price]]></category>
		<category><![CDATA[ICE Certification XLPE Fire Resistant Cable With 25 Years Manufacturer]]></category>
		<category><![CDATA[low-smoke halogen free flame retardant]]></category>

		<guid isPermaLink="false">https://indonesian.baoliyy.com/fire-retardant-cable-fire-resistant-frc-power-cable/</guid>
				<description><![CDATA[&#160; aplikasi digunakan untuk transmisi tenaga dan jalur distribusi dengan tegangan dinilai pada 35kv dan di bawah . dibandingkan dengan pvc terisolasi kabel power , xlpe kabel listrik menawarkan tidak hanya karakteristik listrik yang sangat baik , mekanisme , panas dan penuaan &#8211; tahan , lingkungan stres &#8211; tahan dan kimia tahan korosi , tetapi [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">aplikasi </span></strong></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">digunakan untuk transmisi tenaga dan jalur distribusi dengan tegangan dinilai pada 35kv dan di bawah . dibandingkan dengan pvc terisolasi kabel power , xlpe kabel listrik menawarkan tidak hanya karakteristik listrik yang sangat baik , mekanisme , panas dan penuaan &#8211; tahan , lingkungan stres &#8211; tahan dan kimia tahan korosi , tetapi juga struktur sederhana , ringan , tidak ada pembatasan dengan meletakkan drop , dan suhu tinggi karena suatu hal kerja jangka panjang . </span></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">standar </span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">internasional : IEC 60502-2 , IEC 60228 </span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">cina </span><span style="font-family: arial;color: #231f20;font-size: 10.0pt">: gb / t 12706.2-2008 </span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">standar lainnya seperti </span><span style="font-family: arial;color: #333333;font-size: 10.0pt">bs , din dan icea atas permintaan </span><strong></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">data teknis </span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">tegangan : 0.6 / 1KV , 1.8 / 3kV , 6 / 10kv , 8.7 / 10kv , 8.7 </span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">suhu konduktor maksimum : di bawah normal ( 90 <span style="color: #333333">&deg; c </span>) , darurat ( 130 <span style="color: #333333">&deg; c </span>) atau sirkuit pendek tidak lebih dari 5 s ( 250 <span style="color: #333333">&deg; c </span>) kondisi . </span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">min . ambient temp . </span><span style="font-family: arial;color: #333333;font-size: 10.0pt">&deg; c , setelah instalasi dan hanya jika kabel adalah dalam posisi tetap </span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">min . radius bending : 20 x kabel o.d untuk single core kabel non-armoured </span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x kabel o.d untuk single core kabel lapis baja </span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x kabel o.d untuk multi-core kabel non-armoured </span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">12 x kabel o.d untuk multi-core kabel lapis baja </span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">sertifikat </span></strong></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">ce , RoHS , ccc , kema dan lain lain lagi atas permohonan </span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;</span></strong></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt"><br />spesifikasi </span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 33.0pt" align="left">
<td style="width: 36.8pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjv </span></p>
</td>
<td style="width: 175.2pt;background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">konduktor tembaga , xlpe terisolasi , pvc berselubung kabel listrik </span></p>
</td>
<td style="width: 220.3pt;background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">untuk meletakkan indoor maupun outdoor . mampu menanggung traksi selama instalasi tertentu , tetapi tidak kekuatan mekanik eksternal . meletakkan kabel kawat-tunggal magnetik saluran tidak diperbolehkan . </span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjlv </span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">al . konduktor , xlpe terisolasi , pvc berselubung kabel listrik </span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjy </span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">konduktor tembaga , xlpe terisolasi , pe berselubung kabel listrik </span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">untuk meletakkan indoor maupun outdoor . mampu menanggung traksi selama instalasi tertentu , tetapi tidak kekuatan mekanik eksternal . meletakkan kabel kawat-tunggal magnetik saluran tidak diperbolehkan . </span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjly </span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">al . konduktor , xlpe terisolasi , pe berselubung kabel listrik </span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV22 </span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">xlpe terisolasi , pita baja lapis baja , pvc berselubung kabel listrik </span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">cocok untuk kubur dalam tanah , mampu menanggung kekuatan mekanik eksternal tapi besar menarik kekuatan . </span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV22 </span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">al . terisolasi , pita baja lapis baja , pvc berselubung kabel listrik </span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV32 </span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">konduktor tembaga , xlpe terisolasi , halus kawat baja lapis baja , pvc berselubung kabel listrik </span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">berlaku untuk poros , air dan tanah , mampu menanggung tekanan positif yang lebih besar . </span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV32 </span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">al . konduktor , xlpe terisolasi , halus kawat baja lapis baja , pvc berselubung kabel listrik </span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJV42 </span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">konduktor tembaga , xlpe terisolasi , tebal kawat baja lapis baja , pvc berselubung kabel listrik </span></p>
</td>
<td style="height: 33.0pt" rowspan="2">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">untuk meletakkan dalam poros , air bawah tanah dan besar diference tingkat , mampu menanggung tekanan mekanis dan moderat menarik kekuatan eksternal . </span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">YJLV42 </span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">al . konduktor , xlpe terisolasi , tebal kawat baja lapis baja , pvc berselubung kabel listrik </span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-family: arial;font-size: 10.0pt">&nbsp;</span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://indonesian.baoliyy.com/fire-retardant-cable-fire-resistant-frc-power-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
