<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>flat SE cable &#8211; JYTOP Cable</title>
	<atom:link href="https://indonesian.baoliyy.com/tag/flat-se-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://indonesian.baoliyy.com</link>
	<description>Memproduksi KONDUKTOR AAC / AAAC / ACSR, Kabel XLPE, Kabel PVC, Kabel ABC, Kabel Listrik</description>
	<lastBuildDate>Mon, 16 Sep 2019 15:15:55 +0000</lastBuildDate>
	<language>id-ID</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.26</generator>
	<item>
		<title>6AWG 8AWG copper conductor round or flat shape SE cable</title>
		<link>https://indonesian.baoliyy.com/6awg-8awg-copper-conductor-round-or-flat-shape-se-cable/</link>
				<comments>https://indonesian.baoliyy.com/6awg-8awg-copper-conductor-round-or-flat-shape-se-cable/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 15:15:55 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[flat SE cable]]></category>
		<category><![CDATA[round SE cable]]></category>
		<category><![CDATA[SE cable]]></category>

		<guid isPermaLink="false">https://indonesian.baoliyy.com/6awg-8awg-copper-conductor-round-or-flat-shape-se-cable/</guid>
				<description><![CDATA[copper conductor round or flat shape SE cable, &#160; Service Entrance Cable, Type SE, In flat and In round cable, 600 Volt Concentric conductor with 100% and non 100% coverage Individual Conductors Rated XHHW-2 or THW Jacket and Individual Conductors Sunlight Resistant &#160; APPLICATIONS These requirements cover Type USE and USE-2 (below-ground) and Type SE [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><span style="font-size: 14.0px">copper conductor round or flat shape SE cable,</span></p>
<p>&nbsp;</p>
<p style="text-align: left" align="right"><span style="font-family: arial;color: #000000;font-size: 14.0px">Service Entrance Cable, Type SE, In flat and In round cable, 600 Volt</span></p>
<p style="text-align: left" align="right"><span style="font-family: arial;color: #000000;font-size: 14.0px">Concentric conductor with 100% and non 100% coverage</span></p>
<p style="text-align: left" align="right"><span style="font-family: arial;color: #000000;font-size: 14.0px">Individual Conductors Rated XHHW-2 or THW</span></p>
<p style="text-align: left" align="right"><span style="font-family: arial;color: #000000;font-size: 14.0px">Jacket and Individual Conductors Sunlight Resistant</span></p>
<p style="text-align: left" align="right">&nbsp;</p>
<p><strong></strong><strong><span style="font-family: arial;color: #3073c8;font-size: 16.0pt">APPLICATIONS</span></strong></p>
<p><span style="font-family: arial;font-size: 14.0px">These requirements cover Type USE and USE-2 (below-ground) and Type SE (above-ground) power cables for installation in accordance with Article 338 and other applicable parts of the National Electrical Code (NEC). These cables are for the service-entrance and other (NEC) uses described in 1.4 &ndash; 1.8. In a multiple-conductor cable that is other than submersible-pump cable and does not have a grounding conductor it is appropriate to have one circuit conductor without insulation. It is also appropriate for a submersible pump cable to have a grounding conductor and for Type USE and USE-2 cables to have an insulated grounding conductor. Each insulated conductor in these cables is rated for 600 V. Type USE cable has thermoset insulation, except for the HDPE portion of HDPE-over-XLPE insulation where used for single-conductor Type USE cable. Type SE cable has thermoset or thermoplastic insulation.</span></p>
<p><span style="font-family: arial;font-size: 14.0px">&nbsp;</span></p>
<p><strong></strong><strong><span style="font-family: arial;color: #3073c8;font-size: 16.0pt">SPECIFICATIONS</span></strong></p>
<p><span style="font-family: arial;color: black;font-size: 14.0px">Type SE cable meets or exceeds UL Standard 44 for XHHW-2 conductors or UL 83 for THW conductors, UL Standard 854.</span></p>
<p>&nbsp;&nbsp;</p>
<p><strong><span style="font-family: arial;color: #3073c8;font-size: 16.0pt">CONSTRUCTION</span></strong></p>
<p><span style="font-size: 14.0px"><span style="font-family: arial;color: black">Type SE cable is constructed with sunlight resistant Type XHHW-2 conductors or Type THW conductors. Copper conductors are annealed (soft) copper. Cable assembly plus reinforcement tape are jacketed with sunlight resistant </span><span style="font-family: arial">thermoset or thermoplastic material,<span style="color: black"> Available as 1 conductor with a concentric ground, 2 conductor with a round and flat or concentric round, or 3 conductor with a bare ground. SE cable is jacketed with gray sunlight resistant </span>thermoset or thermoplastic material</span></span></p>
<p><strong><span style="font-family: arial;color: #3073c8;font-size: 16.0pt">TYPE</span></strong></p>
<p>S<span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">ingle conductor type round without 100% coverage</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Single conductor type round with 100% coverage</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Two conductor without concentric conductor</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Three conductor without concentric conductor</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Two conductor type round concentric conductor without 100% coverage </span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Two conductor type flat concentric conductor with inner covered without 100% coverage</span></p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Three conductor concentric conductor without 100% coverage</span></p>
<p align="left">&nbsp;</p>
<p align="left"><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Other special characteristics: design and manufacture according to custmers&#039; request</span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://indonesian.baoliyy.com/6awg-8awg-copper-conductor-round-or-flat-shape-se-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
